User's Manual Part 2
T
2
CAS / Part No. 9000000
SYSTEM DESCRIPTION AND INSTALLATION MANUAL
34-43-20
15 Feb 2003
Use or disclosure of information on this page is subject to the restrictions in the proprietary notice of this document.
4--23
Table 4--1. TT--950/951/952 T
2
CAS Computer Unit Interface Description (cont)
Connector Pin
Designation
Functional Description
J1--5 Output Bus Shields
The shields from the output bus (J1--8, 9) should be connected to this pin.
J1--6,
J1--7
A615A Data Loader Ethernet Output [J1--6 (TD+), J1--7 (TD--)]
TA WS Ethernet 10 Base--T.
J1--8, 9 ARINC 429 Data Loader/PDL Recorder Bus Output: [J1--8 (A), J1--9 (B)]
This differential pair output is a high--speed ARINC 429 bus (100K bits/second nominal)
that is used to output data from the T
2
CAS computer unit to the data loader . The
standards for this interface are defined in ARINC 615 Airborne Computer High Speed
Data Loader.
These pins should be connected to pins 8 and 9 of the PDL cable interface.
J1--10, 11 RS--422 Recorder External Clock Input: [J1--10 (+), J1 --11 ( --)]
These two pins provide external clocking from an RS--422 Flight Data Recorder for
TCAS.
J1--12, 13 RS--422 Recorder Reply Input: [J1 --12 (+), J1 --13 (--)]
These two pins provide communication from a RS--422 Flight Data Recorder for TCAS.
J1--14 RS--422 Recorder 125 kHz/ External Program Pin
This pin is used to designate internal or external recorder clock operation for TCAS. A
ground on this pin selects external recorder clock operation. An open selects 125k Hz
internal recorder clock operation.
J1--15 RS--422 Recorder Disable Program Pin
This program pin is used to enable or disable the RS--422 Data Recorder function for
TCAS. The program pin is activated externally by the Flight Data Recorder. Logic is as
follows:
Ground = RS--422 Recorder disabled; Open = RS--422 Recorder enabled
J1--16 Input Bus Shields
The shields from the input bus (J1--1, 2) should be connected to this pin.
J1--17 Spare Pin
J1--18 PDL Link A Discrete Input
This is a ground/open discrete (Note 1) from an portable ARINC 615 or ARINC 603 data
loader which indicates, to the T
2
CAS computer unit, that a data loader is connected. A
ground indicates a data loader is connected. This pin is used by the TCAS, TAWS/RWS
and GPS.
J1--19 PDL Link B Common
Connect this pin to pin 19 of the PDL cable interface.