User's Manual Part 2

T
2
CAS / Part No. 9000000
SYSTEM DESCRIPTION AND INSTALLATION MANUAL
34-43-20
15 Feb 2003
Use or disclosure of information on this page is subject to the restrictions in the proprietary notice of this document.
6--27
Table 6--3. Computer Unit Self--Test Execution (cont)
Test Sequence Test IndicationsActivation
Push the PUSH TO TEST
button again before the
previous 10--second display
period has elapsed
Previous fault display is aborted
All T
2
CAS TCAS lamps come on during a
1--second lamp test
All front T
2
CAS TAWS/RWS LEDs will be lit
for 1 second (+/-- 0.5 seconds) in the
following colors:
-- TAWS P/F STATUS: Red
-- TAWS I/O FAIL: Red
-- TAWS APM FAIL: Red
-- XFER IN PROCESS: Green
-- C/F LOAD STATUS: Red
The TAWS/RWS XFER IN PROCESS LED
will be extinguished.
The TCAS Status/fault data recorded
during the preceding flight leg is displayed
for 10--seconds.
The TA WS/RWS Status/fault data recorded
during the preceding flight leg is displayed
for approximately 11 seconds.
Push the PUSH TO TEST
button before the end of each
succeeding display period
TCAS and TA WS/RWS Status/fault data
recorded during a total of 10 flight legs
(maximum) is displayed
When data from the earliest recorded flight
leg has been displayed, all lamps flash at
approximately a 2.5--Hz rate for 3--seconds
if the PUSH TO TEST button is pushed.
This indicates the end of recorded test
data.