User's Manual Part 2

T
2
CAS / Part No. 9000000
SYSTEM DESCRIPTION AND INSTALLATION MANUAL
34-43-20
15 Feb 2003
Use or disclosure of information on this page is subject to the restrictions in the proprietary notice of this document.
6--14
BCA EFIS 0 RA/TA block transfer program that determines the type of
data transfer from the T
2
CAS CU to the TA/RA displays:
A(1) indicates Honeywell BCA EFIS format. A (0) indicates
ARINC 735 format: RMP--12C.
CABLE DELAY
PROG
000 RF delay compensation program for antenna cable length
difference (top versus bottom): RBP--7G, RBP--7H, RBP--7J
TEST MODE 0000 Shop test function (all 0s for flight mode):
RBP--9D, RBP--9E, RBP--9F, RBP--9G
FUNCT TEST INH 0 Inhibits Flight Deck self--test when airborne (0 for no inhibit):
RBP--8E
SIM SOFT ENABLE 0 Simulator Software Enable input: RBP--10K
Should always be (0) for flight mode.
MAX # INTRUDER 00000 Select maximum number of traffic symbols displayed on VSI.
Value for each digit, from left to right, is 16, 8, 4, 2, 1. The
maximum number is the sum of not selected values (0s):
RBP--8F, RBP--8G, RBP--8H, RBP--8J, RBP--8K.
DISP THREATS
ONLY
0 Selects display of traffic only when TAs or RAs occur:
(0 indicates display of any traffic): RBP--7F.
GND DISPLAY
MODE
0 Selects TCAS OFF automatically with aircraft ON GROUND
(0 indicates TCAS active ON GROUND): RBP--7E.
Selection of code 0006 displays the third of three pages that define the Program
Pins status. See Figure 6--8.
Figure 6--8. Typical Program Pins 3/3 Page