User's Manual Part 2
T
2
CAS / Part No. 9000000
SYSTEM DESCRIPTION AND INSTALLATION MANUAL
34-43-20
15 Feb 2003
Use or disclosure of information on this page is subject to the restrictions in the proprietary notice of this document.
5--17
Figure 5--3. RS--232 PC to TCAS Interface Cable
(3) TAWS/RWS Software Verification Using a Stand--Alone PC ONLY
Verify the updated TAWS/RWS software/Database part numbers using a stand-- alone
PC according to the followin g procedure.
(a) Obtain PC software tool EDDIT, Part No. PS4088035--101.
(b) Obtain or build an RS--232 cable. (Refer to Figure 5-- 3.)
(c) Shut down and power off the PC.
(d) Remove power from the TT--950/951/952 Computer Unit.
(e) Connect the RS--232 cable from the PC (9--pin connector) to the J1 front
connector on the TT--950/951/952 Computer Unit.
(f) Apply power to the TT--950/951/952 Computer Unit.