User's Manual Part 2
T
2
CAS / Part No. 9000000
SYSTEM DESCRIPTION AND INSTALLATION MANUAL
34-43-20
15 Feb 2003
Use or disclosure of information on this page is subject to the restrictions in the proprietary notice of this document.
5--16
(a) Obtain PC software Part No. PS4088035--101.
(b) Obtain or build an RS--232 cable. (Refer to Figure 5-- 3.)
(c) Shut down and power off the PC.
(d) Remove power from the TT--950/951/952 Computer Unit.
(e) Connect the RS--232 cable from the PC (9--pin connector) to the J1 front
connector on the TT--950/951/952 Computer Unit.
(f) Apply power to the TT--950/951/952 Computer Unit.
(g) Power on the PC to Microsoft Windows operation.
(h) On the PC, go to START => PROGRAMS => HONEYWELL TOOLS and double
click “TCAS Part Number”.
(i) Verify the updated TCAS software part number.
(j) Shut down and power off the PC.
(k) Remove power from the TT --950/951/952 Computer Unit.
(l) Disconnect the RS--232 cable from the J1 front connector on the
TT--950/951/952 Computer Unit.