SYSTEM DESCRIPTION AND INSTALLATION MANUAL
34-43-20
15 Feb 2003
Use or disclosure of information on this page is subject to the restrictions in the proprietary notice of this document.
1--46
Table 1--9. VSI/TRA Leading Particulars
Item Specification
Dimensions (maximum):
Height ....................................... 3.26 in. (82.8 mm)
Width ........................................ 3.26 in. (82.8 mm)
Length ....................................... 7.5 in. (190.0 mm)
Weight (maximum) .............................. 3.3lb(1.5kg)
Power Requirements:
Primary ...................................... 115 V, 400 Hz; 17 Watts nominal (Day),
12 Watts nominal (Night),
20 Watts maximum
ExternalCircuitBreakerRating.................. 1Ampat115Vac
DisplayType.................................... Liquid Crystal
Mating Connectors:
J1(41Pin) ................................... M83723/72R--20--41--6
Mounting ....................................... 3--ATI Clamp, Marmon NH1004994--30
or MSP 64311B
(1) Functional Description and Operation
The VSI/TRA has three functions. It continuously displays rate of climb or rate of
descent. Traffic information is displayed and resolution advisory informa tion is
displayed against vertical speed to allow the flight crew to avoid threats.
The vertical speed display is generated from signals applied directly to the indicator.
The VSI/TRA is designed to be used in place of a conventional vertical speed
indicator. Four possible sources exist for vertical speed data including ARINC 429
data, DC analog signals in accordance with ARINC 575 (approximately 500 mV per
1000 ft/min), ac analog signals in accordance with ARINC 565 (approximately 250
mV per 1000 ft/min), and ARINC 429 signals from the ACSS Pressure Transducer
Module. The VSI/TRA computes vertical rate from electrical static pressure when a
remote static sensor is used. These four program pin selectable configurations
provide compatibility with most aircraft.
Various dash number VSI/TRA Displays are available that provide unique design
characteristics, which include VSI rate filter programming and selection of an English
or metric rate scale. Table 1--5 contains a listing of all the VSI/TRA configurations.