User's Manual Part 1

T
2
CAS / Part No. 9000000
SYSTEM DESCRIPTION AND INSTALLATION MANUAL
34-43-20
15 Feb 2003
Use or disclosure of information on this page is subject to the restrictions in the proprietary notice of this document.
1--29
10
Voice Audio Outputs
The TCAS function contains two analog audio outputs that provide TCAS
aural traffic advisories and resolution advisories. The 8--ohm output has the
capability to supply up to 8 Watts RMS into a speaker. The 600--ohm output
has the capability to supply up to 80 milliwatts RMS into an audio distribution
system.
11
RS -- 232 Interface
The TCAS function has an RS--232 input/output for connection to a personal
computer. The interface allows for LRU maintenance and troubleshooting.
The maintenance log and RA event log can also be downloaded to a PC
using this port. The RS--232 interface is connected to the 53-- pin PDL
connector on the front of the unit.
12
Altitude Alerter Interface
The TCAS function contains an ARINC 429 low speed input bus that is
reserved for receiving selected altitude information from an altitude control
source or flight control computer. The TCAS function uses the selected
altitude information to inhibit the weakening of a resolutio n advisory by
determining the selected altitude limits for the aircraft.
13
Reserved ARINC 429 Bus Interface
The TCAS function has four sets of reserved ARINC 429 input buses
configured as either high speed or low speed. These buses allow for future
upgrades to the TCAS system without hardware modification.
(c) TAWS/RWS System Interfaces
1
Onboard Maintenance System Interface
The TAWS/RWS function contains a set ASDB defined ARINC 429 low
speed buses for communication with an onboard maintenance system (1
input, 1 output). The unit interfaces with all major airframe manufacturers
maintenance computer systems. Since the maintenance computer protocol
for each airframe manufacturer is different, the T
2
CAS computer uses
information from the Aircraft Personality Module (APM) to determine what
OMS system, if an y, is insta lled.
2
Data Loader Interface
The TAWS/RWS function is provisioned for interface with an ARINC 615A
data loader (Ethernet 10 Base--T). The front Portable Data Loader
connector contains the signals required by the ARINC 615A specification.
The interface will be used to upload future software updates to the
TAWS/RWS system.