Table 1--6. TT--950/951/952 T
2
CAS Computer Unit Leading Particulars
Item Specification
Dimensions (maximum):
Height ....................................... 7.64 in. (194.0 mm)
Width (TT--950/TT--952) ........................ 7.52 in. (191.0 mm)
Width (TT--951) ............................... 4.90 in. (124.5 mm)
Length ....................................... 15.26 in. (387.6 mm)
Weight (maximum):
TT--950 ...................................... 17.60 lb (8.0 kg)
TT--951 ...................................... 15.40 lb (7.0 kg)
TT--952 ...................................... 18.60 lb (8.45 kg)
Operating Voltage:
dcVoltage.................................... +20.5 V dc minimum, +27.5 V dc
nominal, +32.2 V dc maximum
ac V oltage (TT--950/TT--952 only) ............... 97 V rms minimum, 115 V rms nominal,
134 V rms maximum at 400 ¦ 80 Hz
Power Consumption (TT--950/TT--951) ............. 70 Watts standby, 100 Watts operational
Power Consumption (TT--952) .................... 83 Watts standby, 113 Watts operational
Circuit Breaker Ratings:
115VacCircuitBreaker ....................... 5 Amp Typical
28VdcCircuitBreaker ........................ 10 Amp T ypical
Mating Connector:
P1 (Rear Connector) ........................... Radiall Part No. 620--800--066
J1 (Front Connector) .......................... ACSS Part No. 4004295--160,
ITT Part No. KJ6F18A53P
Cooling Requirements:
6 MCU Units (TT--950/952):
-- Cooling Requirements ....................... ARINC 600 (blow through) or ARINC
404 (draw through)
-- MinimumCoolingAirflowRate ................ 54.7 pounds/hour (24.86 Kg/hour)
-- PressureDrop(atminairflowrate) ............ 0.2 ± 0.12 inches (5 ± 3 millimeters) of
water
4 MCU Units (TT--951):
-- Cooling Requirements ....................... NONE -- Unit has an internal fan for
cooling. No forced air cooling is required
or accepted.
-- FanOn(controlledbytemperaturesensor) ..... Temp sensor > +45 Deg C