User's Manual Part 1
T
2
CAS / Part No. 9000000
SYSTEM DESCRIPTION AND INSTALLATION MANUAL
34-43-20
15 Feb 2003
Use or disclosure of information on this page is subject to the restrictions in the proprietary notice of this document.
1--78
Figure 1--31. Terrain Hazard Display Upon An Avoid Terrain Warning
(4) TAWS/RWS Aural Messages
Aural alerts can be generated for any of the cautions or warnings generated by the
TAWS and RWS functions. The specific messages are selectable from a list of
several options. Additionally, the T
2
CAS can be configured to play the voices in
either a male voice or a female voice. The list of selectable aural alerts is shown in
Table 1--13.
Table 1 -- 13. TAWS/RWS Aural Alerts
Condition Selectable Aural Alerts
CPA Caution “Terrain Ahead”
or
“Terrain Caution”
CPA Warning -- Pull up “Terrain Ahead, Pull Up”
or
“Terrain, Terrain, Pull Up, Pull Up”
or
Whoop Whoop, “Pull Up”
CPA Warning -- Avoid Terrain “Avoid Terrain”
Mode 1 Caution Whoop Whoop, “Pull Up”
or
“Pull Up, Pull Up”
Mode 1 W arning Whoop, Whoop, “Pull Up”
or
“Pull Up, Pull Up”