User's Manual
SYSTEM DESCRIPTION AND INSTALLATION MANUAL
TCAS 3000 Traffic Alert and Collision Avoidance System
34−43−23
Use or disclosure of information on this page is subject to the restrictions in the proprietary notice of this document.
Page 1−2
15 Dec 2005
Table 1−1. System Components Supplied by ACSS
Component Model No. ACSS Part No.
TCAS Computer Unit (6−MCU size unit) −−−− 9003000−10yyy
(Note 1.)
TCAS Computer Unit (4−MCU size unit) −−−− 9003000−55yyy,
−65yyy
(Note 1.)
Directional Antenna (See Table 1−3 for configuration
descriptions)
−− 7514081−VAR or
7514060−VA R
Control Panel (See Table 1−4 for configuration descriptions) −− 4052190−VA R
VSI/TRA Display (See Table 1−5 for configuration
descriptions)
−− 4067241−VA R
Pressure Transducer Module (PTM) −− 4067487−901
(Note 2.)
PTM Mounting Bracket, Right Angle −− 4067487−901
PTM Mounting Plate, 3−ATI Panel Mount −− 4067492−VA R
(Note 3.)
Mode S Data Link Transponder (4−MCU size unit) XS−950 7517800−xxyyy
Diversity Mode S Transponder RCZ−852 7510700−850/−951
Installation Kit for RCZ−852 Mode S Transponder
(Contains mounting tray, 106 pin ARINC 404 mating
connector and two TNC RF jack connectors)
IK−415 7510707−968
NOTES:
1. The last three digits of the five digit dash number (yyy) correspond to the unit software
version.
2. The PTM is only required on installations that use a ACSS VSI/TRA display where no
electrical vertical speed data in a compatible format is available.
3. The 3−ATI panel mount comes in three different color options: −901 (gray), −902 (brown),
and −903 (black).