User's Manual
SYSTEM DESCRIPTION AND INSTALLATION MANUAL
TCAS 3000 Traffic Alert and Collision Avoidance System
34−43−23
Use or disclosure of information on this page is subject to the restrictions in the proprietary notice of this document.
Page 3−53
15 Dec 2005
Table 3−8. RCZ−852 Diversity Mode S Transponder Interconnect Data (cont)
I/O NotesConnects To
Connector
Pin
Description
Reserved J1−89
(O) XPDR STRAP +5V J1−90 (26) Strap Board (Red) 4
(O) XPDR STRAP CLK (N) J1−91 (26) Strap Board (Blue) 4
(O) XPDR STRAP LOAD (N) J1−92 (26) Strap Board (Orn) 4
(I) XPDR STRAP DATA (P) J1−93 (26) Strap Board (Wht) 4
(I) ENC ALT2 A2 (N) J1−94 (24) Encoding Altm #2
(I) ENC ALT2 A4 (N) J1−95 (24) Encoding Altm #2
(I) ENC ALT2 B1 (N) J1−96 (24) Encoding Altm #2
(I) ENC ALT2 B2 (N) J1−97 (24) Encoding Altm #2
(I) ENC ALT2 B4 (N) J1−98 (24) Encoding Altm #2
(O) XPDR ACTIVE (NO) J1−99 (24) Antenna Switching
Relay
4
(O) XPDR VALID (NO) J1−100 (24) Control Panel
Reserved J1−101
(O) ALT VALID (NO) J1−102 (24) Control Panel 5
(O) XPDR STRAP GND J1−103 (26) Strap Board (Blk) 4
(O) XPDR STRAP PGM (N) J1−104 (26) Strap Board (Grn) 4
(O) XPDR STRAP PGM (P) J1−105 (26) Strap Board (Yel) 4
− POLARIZATION PIN J1−106 NC
(I) Bottom Antenna RF Input J2 coax Bottom Antenna
(I) Top Antenna RF Input J3 coax Top Antenna
NOTES:
1. Use AWG−24 single conductor, shielded wire. Attach shield to ground loop E1 or E2 on back of
mounding tray.
2. Two wire shielded cable. Tie shields to ground loop E1 or E2 located on back of mounting tray.
3. This ARINC 429 output is required on some Collins Control Panels that require a feedback loop to
make sure the transponder is working properly.
4. Refer to interface descriptions in Table 4−9.
5. This output is connected only if the control panel has an ALT FAIL input function.