User's Manual
SYSTEM DESCRIPTION AND INSTALLATION MANUAL
TCAS 3000 Traffic Alert and Collision Avoidance System
34−43−23
Use or disclosure of information on this page is subject to the restrictions in the proprietary notice of this document.
Page 1−43
15 Dec 2005
Table 1−11. XS−950 Data Link Transponder Leading Particulars
Item Specification
Dimensions (maximum):
• Height . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7.6 in. (192 mm)
• Width . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.9 in. (124.5 mm)
• Length . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15.2 in. (386 mm)
Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11.5 lb (5.2 kg)
Power Requirements (115 V ac version):
• Operating Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97 to 134 V rms, 115 V rms nominal
• Operating Frequency . . . . . . . . . . . . . . . . . . . . . . . . . 320 to 480 Hz, 400 Hz nominal
• Power Consumption:
− Standby Mode (No Replies) . . . . . . . . . . . . . . . . . 40 Watts maximum
− Active mode (Maximum Load) . . . . . . . . . . . . . . . 85 Watts maximum
• External Circuit Breaker Rating . . . . . . . . . . . . . . . . . 5 A at 115 V ac, 400 Hz
Power Requirements (28 V dc version):
• Operating Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . +18.0 to +32.2 V dc, +27.5 V dc nominal
• Power Consumption:
− Standby Mode (No Replies) . . . . . . . . . . . . . . . . . 40 Watts maximum
− Active mode (Maximum Load) . . . . . . . . . . . . . . . 85 Watts maximum
• External Circuit Breaker Rating . . . . . . . . . . . . . . . . . 7 A at 28 V dc
Mating Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Radial Part No. NSXN2P203X0005
Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ARINC 600 4MCU Tray Assembly
TSO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C112, CL043, 121, F11
Environmental Specifications: . . . . . . . . . . . . . . . . . . . . DO−160C Environmental Category
− 115 V ac version . . . . . . . . . . . . . . . . . . . . . . . . . . . [A2E1]−BB[CLMY]XXXXXXZEAEZRZA3E3XX
− 28 V dc version . . . . . . . . . . . . . . . . . . . . . . . . . . . [A2E1]−BB[CLMY]XXXXXXZ[BZ]AZZRZA3E3XX
• Temperature / Altitude [A2E1]:
− Operating Temperature . . . . . . . . . . . . . . . . . . . . . −55 to +70 degrees C
− Ground Survival Temperature . . . . . . . . . . . . . . . −55 to +85 degrees C
− Altitude . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Sea Level to 70,000 feet
− Loss of Cooling . . . . . . . . . . . . . . . . . . . . . . . . . . . . +40 degrees C for 30 minutes minimum