Table 41. TCAS 3000 Computer Unit Loading/Gradient Specifications (cont)
Connector Pin
Designation
Functional Description
RMP10A
RMP10B
RMP10C
ADSB Program Inputs
Reserved for future use.
RMP10D Single Mode S Transponder Input
This pin must be grounded when system is configured with a single Mode S transponder.
Failure to ground this program pin in a single Mode S installation will result in XPNDR bus
faults displayed on fault data LEDs.
RMP10E
Thru
RMP10J
Reserved Program Inputs
Reserved for future use.
RMP10K ADSB Surveillance Program Input
This program pin enables passive surveillance using ADSB DF17 extended squitters.
A ground on this pin enables ADSB surveillance and an open disables ADSB
surveillance.
RMP11A Reserved Program Input
Reserved for future use.
RMP11B Traffic Display of Flight ID Program Input
This program pin allows traffic display of flight identification information from a
transponder to be output on the TA/TA displays. A ground on this pin enables this
function and an open disables the function.
RMP11C Male Voice Program Input
This program input is intended to allow audio annunciation to be selectable for either male
or female genders. A ground on this pin selects the male voice and an open selects the
female voice.
RMP11D Flight Data Recorder ARINC 429 and Extended Maintenance Log Program Input
This program pin is used to specify whether the ARINC 429 Flight Data Recorder (FDR)
is to be used. An open on this pin means that the FDR is not utilized. A ground indicates
that flight data is output as highspeed ARINC 429 data on RA Display No. 1 and No. 2
busses. While the FDR is enabled, normal lowspeed RA display bus operation is not
available. A ground also enables RA/TA events recording in memory.
RMP11E
Thru
RMP11K
Reserved Data Bus Inputs
Reserved for future use.
RMP12A Reserved Program Input
Reserved for future use.