SYSTEM DESCRIPTION AND INSTALLATION MANUAL
T
3
CAS/Part No.9005000
Table 4-8: Operator Selectable Options Default Settings (cont)
Operator Selectable
Options
Data Parameter Selectable Option
Aural Alert
Prioritization Input 4
Enable (NOTE)
AURAL_ALERT_
PRIORITIZATION_INPUT_4_
ENABLE
Enable - Inhibits Aural
alerts that are of lesser
priority than Aural Alert
Priority 4.
Disable - Lesser priority
aural alerts Not
inhibited.
Visual Alert
Prioritization Input 4
Enable (NOTE)
VISUAL_ALERT_
PRIORITIZATION_INPUT_4_
ENABLE
Enable - Inhibits Visual
alerts that are of lesser
priority than Visual
Alert Priority 4.
Disable - Lesser priority
Visual alerts Not
inhibited.
Store GCAM Prior
Data Duration
STORE_GCAM_PRIOR_DATA
_DURATION
Represents the time
duration of GCAM
Event and GCAM
parameter data to be
recorded prior to an
event start.
Mode 6 Volume Level
Disable-System Test
Callouts
MODE_6_VOLUME_LEVEL_DI
SABLE_SYSTEM_TEST_CALL
OUTS
False to cause System
Test Callouts indicated
to be annunciated at
the Mode 6 Volume
Level.
True to cause System
Test Callouts to be
annunciated at the
High-Impedance or
Low-Impedance
Normal Volume Levels.
BITE Fault Aurals
Enable
BITE_FAULT_AURALS_ENABLE
Enabled - the
TAWS_FCI will aurally
annunciate faults via
Extended self-test or
Maintenance Report
4-104
04 Nov 2014
34-45-29
Pub. No. 8600200-001, Revision 004