User's Manual

Table Of Contents
SYSTEM DESCRIPTION AND INSTALLATION MANUAL
T
3
CAS/Part No.9005000
Table 4-8: Operator Selectable Options Default Settings (cont)
Operator Selectable
Options
Data Parameter Selectable Option
Mode 2 Warning Alert MODE_2_WARNING
1 = Whoop, Whoop,
“PULL UP” or
2 = “PULL UP, PULL
UP”
Mode 3 Caution Alert MODE_3_CAUTION
1 = “DON’T SINK,
DON’T SINK”
Mode 4A Caution
Alert
MODE_4A_CAUTION
1 = “TOO LOW
TERRAIN”
Mode 4B Caution
Alert
MODE_4B_CAUTION
1 = “TOO LOW GEAR
2 = “TOO LOW FLAPS
Mode 5 Caution Alert
MODE_5_CAUTION
1 = “GLIDESLOPE”
Mode 6 High-
Impedance Volume
Level (NOTE)
MODE_6_HIGH_IMPEDANCE_
VOLUME_LEVEL
integer in the range 0 ..
255
( min = 0, max = 255)
Mode 6 Low-
Impedance Volume
Level (NOTE)
MODE_6_LOW_IMPEDANCE_
VOLUME_LEVEL
integer in the range 0 ..
255
( min = 0, max = 255)
Mode 6 Volume Level
Enable - Altitude
Callouts (NOTE)
MODE_6_VOLUME_LEVEL_
ENABLE_ALTITUDE_
CALLOUTS
Enable - Altitude
Callouts annunciated at
the Mode 6 Volume
Level.
Disable - Altitude
Callouts annunciated at
the High-Impedance or
Low-Impedance
Normal Volume Levels.
Mode 6 Volume Level
Enable - Bank Angle
Callouts (NOTE)
MODE_6_VOLUME_LEVEL_
ENABLE_BANK_ANGLE_
CALLOUTS
Enable - Bank Angle
Callouts annunciated at
the Mode 6 Volume
Level.
Disable - Bank Angle
Callouts annunciated at
the High-Impedance or
Low-Impedance
Normal Volume Levels.
Pub. No. 8600200-001, Revision 004
34-45-29
4-99
04 Nov 2014
Use or disclosure of information on this page is subject to the restrictions in the proprietary notice of this document.