User's Manual

Table Of Contents
SYSTEM DESCRIPTION AND INSTALLATION MANUAL
T
3
CAS/Part No.9005000
Table 4-2: T
3
CAS Computer Unit Interface Description
(Applicable to Part No. 9005000-11801 and -55801)
Connector
Pin
Designation
Functional Description
NOTE 1:
Ground
= Voltage of 0.0 V dc to +3.5 V dc or Resistance of less than 10 ohms
applied to input.
Open = Voltage of +18.5 to +36 V dc or Resistance greater than 100k ohms
applied to input.
NOTE 2:
The Antenna Coad shall be RG225 or equivalent coaxial cable that provides a loss of
2.5 dB ±0.5 dB or less between the T
3
CAS computer and each TCAS Antenna port.
For Directional Antenna Coaxes, each coax cable must be within 0.5 dB of the other
coaxes (e.g., if one port has a 2-dB loss, the other 3 ports cannot exceed 2.5-dB loss.
NOTE 3:
Ground
= Port capable of sinking at least 20 mA of current.
Open
= Voltage of +18.5 to +36 V dc or Resistance greater than 100k ohms
applied to output.
NOTE 4:
Refer to the applicable Interface Control Documents (ICD) for corresponding labels
associated with each bus and label bit definition.
4-70
04 Nov 2014
34-45-29
Pub. No. 8600200-001, Revision 004
Use or disclosure of information on this page is subject to the restrictions in the proprietary notice of this document.