User's Manual

Table Of Contents
SYSTEM DESCRIPTION AND INSTALLATION MANUAL
T
3
CAS/Part No.9005000
Table 4-2: T
3
CAS Computer Unit Interface Description
(Applicable to Part No. 9005000-11801 and -55801)
Connector
Pin
Designation
Functional Description
J1-16
Input Bus Shields
The shields from the input bus (J1-1, 2) should be connected to this pin.
J1-17
Spare Pin
J1-18
PDL Link A Discrete Input
Reserved.
J1-19
PDL Link B Common
Reserved..
J1-20, 22
115 V ac Power Output: [J1-20 (H), J1-22 (C)]
These power output pins provide the 115 V ac operating power for the data loader.
The 115 V ac (H) and 115 V ac (C) interconnect wires should be shielded or twisted
and shielded with an insulating jacket over the shield. The shield should be
connected to chassis ground (J1-21).
J1-21
Chassis Ground
Connect 115 V ac power shields to this pin.
J1-23
A615A Dataloader Ethernet Input (RD+)
TAWS Ethernet 10-base-T read input
J1-24,
Thru
J1-27
Spare Pins
J1-28
Output Bus Shields
J1-29
Thru
J1-32
Spare Pins
J1-33,34
ARINC 429 TA/RA Display No.1 Output: [J1-33 (A), J1-34 (B)]
This bus can be used to connect to a maintenance display. These pins are also
connected to the ARINC 600 connector on the rear of the unit (RMP-7C and -7D).
J1-35,
J1-36
Spare Pins
J1-37, 38
28 V dc Power Output: [J1-37 (HI), J1-38 (LO)]
These pins supply +28 V dc, 30 W nominal power for a portable data loader (PDL).
These pins are used only if the PDL operates from +28 V dc.
J1-39
A615A Dataloader Ethernet Input (RD-)
TAWS Ethernet 10-base-T read input
J1-40
RS-232 Data Input #1
This input is used by the T
3
CAS to receive RS- 232 data from a portable
maintenance terminal.
4-68
04 Nov 2014
34-45-29
Pub. No. 8600200-001, Revision 004