Table 6-10: Computer Unit Self-Test Execution (cont)
Test Sequence
Activation
Test Indications
Commanded Self-Test
Push the PUSH-TO-
TEST button again
before the previous 11-
sec display period has
elapsed
Previous fault display is aborted.
All T
3
CAS lamps come on during a
1-sec lamp test.
All front T
3
CAS LEDs will be lit for
1 sec0.2 sec) in the following
colors:
- T
3
CAS P/F STATUS: Red
- Data Status: Amber
- APM Status: Amber
- Top Ant: Amber
- Bot Ant: Amber
- External IO Status: Amber
The T
3
CAS Status/fault data
recorded during the preceding
flight leg is displayed for 11 sec.
Push the PUSH-TO-
TEST button before the
end of each
succeeding display
period
T
3
CAS Status/fault data recorded
during a total of 10 flight legs
(maximum) is displayed
When data from the earliest
recorded flight leg has been
displayed, all lamps flash at
approximately a 2-Hz rate for 3
sec if the PUSH-TO-TEST button
is pushed. This indicates the end
of recorded test data.
Pub. No. 8600200-001, Revision 004
34-45-29
6-55
04 Nov2014