User's Manual
Table Of Contents
- T3CAS_Section_5
- 5 Adjustment/Test
- 1. General
- 2. Equipment
- 3. Initial Harness Checkout (New Installations Only)
- 4. System Self-Tests
- 5. Return-to-Service Test
- 6. Operational Software Loading Using an ARINC 615A Portable Data Loader or Compact Flash Card
- 7. Downloading Information from the TP3PCAS Using a CF Card
- 1. Obtain a New or Blank Compact Flash (CF) card.
- 2. Copy to the New or Blank CF card the appropriate ‘Header File’
- a) Header files are files copied to the New or Blank CF card that will instruct the computer unit what is desired to be downloaded.
- b) Header files needed to download Maintenance Data, Event Data and CRC Part Numbers can be obtained from ACSS Customer Services at +1-623-445-7070 or crc.acss@l-3com.com.
- 3. For downloading Maintenance Data, Event Data or CRC Part Numbers the aircraft does not need to be in an on-ground configuration.
- 4. Apply power to the computer unit.
- 5. Insert the CF card.
- 6. For ACSS part numbers 9005000-10000, -10101, -10202, and -10204 the DATA STATUS LED will UblinkU green once; this indicates the unit recognized that a CF card was inserted.
- 7. For ACSS part numbers 9005000-11203, -11801 and -55801 the DATA STATUS LED will UblinkU green while reading the header file and performing the action defined in the header file.
- 8. Flight Data Recording
- 1. T3CAS part numbers 9005000-10000, -10101, -10202, and -10204 only support FAT16 CF card formatting. T3CAS part numbers 9005000-11203, -11801 and -55801 support both FAT16 and FAT32 CF card formatting.
- B. Flight Data
- 1. Obtain a New or Blank CF Card.
- 2. Copy to the New or Blank CF Card the Appropriate Header File.
- 3. Header files are files copied to the New or Blank CF card that will instruct the computer unit what is desired to be downloaded.
- 4. For Flight Data Recording, the aircraft does not need to be in an on-ground configuration.
- 5. Apply power to the computer unit.
- 6. Insert the CF card.
- B. Flight Data
- 9. Downloaded Maintenance Data, Event Data And Flight Data May Be Sent To ACSS Customer Services For Analysis
- 5 Adjustment/Test
- T3CAS_Section_6
- T3CAS_Section_7
- 7 Maintenance Practices
- 1. General
- 2. Equipment and Materials
- 3. Procedure for the TP3PCAS Computer Unit
- 4. Procedure for the APM (Not applicable for part numbers 9005000-10000, -10101, -10202, -10204, or -11203)
- 5. Procedure for the Directional Antenna
- 6. Procedure for the Omnidirectional Antenna (Applicable to part numbers 9005000-11203, -11801 and -55801)
- 7. Procedure for the Control Panel
- 8. Procedure for the VSI/TRA Display
- 9. Instructions for Continued Airworthiness, FAR Part 25.1529
- 7 Maintenance Practices
- T3CAS_Section_8
- T3CAS_Section_9
- T3CAS_Section_10
- T3CAS_Appendix_A
SYSTEM DESCRIPTION AND INSTALLATION MANUAL
T
3
CAS/Part No.9005000
Table 6-8: Table of ACD Enumerated Values (cont)
ACD Discrete Option
ACD Enumerated
Option Bit Position
ACD Selectable Option
OCPA Mode A Warning
Hex Char 4
1 = “OBSTACLE AHEAD PULL-UP“
2 = “OBSTACLE OBSTACLE PULL-
UP PULL-UP”
3 = “~~PULL UP”
“~~” Designates a pair of constantly
varying tones from 400 to 800 Hz.
The tones are 0.3 sec each,
separated by 0.1 sec and followed by
0.1 sec of silence.
OCPA Mode B Warning
Hex Char 5
1 = “Avoid Obstacle”
Alerting Obstacle Size
Hex Char 6
0 = 16 pixel alerting obstacles
1 = 32 pixel alerting obstacles
Non Alerting Obstacle Size
Hex Char 7
0 = 16 pixel non-alerting obstacles
1 = 32 pixel non-alerting obstacles
The Maintenance ACD Options Page 17/25 displays the ACD Volume Level Options, as
shown in Figure 6-41. The correlations table for the displayed volume level values is
shown in Table 6-9. In the example shown in Figure 6-41, the volume levels are set to a
maximum value of 255.
Figure 6-41: ACD Option Page (Page 17/25) - Volume Level Options
Table 6-10: Table of Volume Level Values (for Page 17/25 and 18/25)
ACD Volume Option
Range
High-Impedance Volume Level
0 ≤ X ≤ 255
Low-Impedance Volume Level
0 ≤ X ≤ 255
Mode 6 High-Impedance Volume Level
0 ≤ X ≤ 255
Mode 6 Low-Impedance Volume Level 0 ≤ X ≤ 255
6-50
04 Nov 2014
34-45-29
Pub. No. 8600200-001, Revision 004
Use or disclosure of information on this page is subject to the restrictions in the proprietary notice of this document.