CAS/Part No.9005000
Figure 6-40: ACD Option Page (page 16/25) Volume Level Options
Table 6-9: Table of ACD Enumerated Values
ACD Discrete Option
ACD Enumerated
Option Bit Position
ACD Selectable Option
Windshear Caution Aural
Hex Char 1
This parameter controls the format of
the Windshear Caution Aural
0 = (Undefined)
1 = “Caution Windshear
Obstacle Max Display Range
Hex Char 2
This value represents the maximum
range beyond which no obstacles are
displayed. The selections for this
value are 5 NMI, 10 NMI,15 NMI, 20
NMI, 25 NMI, 40 NMI, 80 NMI, 160
NMI, or 320 NMI. If the value of the
maximum range is not equal to one of
these values the PSS defaults the
value to 10 NMI.
1 = 5 NMI
2 = 10 NMI
3 = 15 NMI
4 = 20 NMI
5 = 25 NMI
6 = 40 NMI
7 = 80 NMI
8 = 160 NMI
9 = 320 NMI
OCPA Mode Caution
Hex Char 3
1 = “OBSTACLE AHEAD”
2 = “CAUTION OBSTACLE”