User's Manual

Table Of Contents
SYSTEM DESCRIPTION AND INSTALLATION MANUAL
T
3
CAS/Part No.9005000
Table 6-5: ACD Discrete Options (cont)
ACD Discrete Option
ACD Discrete
Option Bit Option
ACD Discrete Option Bit Setting
Mode 6 Volume Level
Enable - Altitude Callouts
Hex Char 1 (MSB),
bit 1
1 = Altitude Callouts annunciated at the
Mode 6 Volume Level,
0 = Altitude Callouts annunciated at the
High-Impedance or Low-Impedance
Normal Volume Levels
Mode 6 Volume Level
Enable - Bank Angle
Callouts
Hex Char 2, bit 4
1 = Bank Angle Callouts annunciated at the
Mode 6 Volume Level,
0 = Bank Angle Callouts annunciated at the
High-Impedance or Low-Impedance
Normal Volume Levels
Mode 6 Volume Level
Enable - Minimum Callouts
Hex Char 2, bit 3
1 = Minimums Callouts annunciated at the
Mode 6 Volume Level,
0 = Minimums Callouts annunciated at the
High Impedance or Low Impedance Normal
Volume Levels
Mode 6 Volume Level
Enable - Mode 5 Callout
Hex Char 2, bit 2
1 = Mode 5 Callouts annunciated at the
Mode 6 Volume Level,
0 = Mode 5 Callouts annunciated at the
High Impedance or Low Impedance Normal
Volume Levels
QFE Enable
Hex Char 2, bit 1
1 = Indicates QFE altitude correction is
enabled,
0 = QNH altitude correction is used
Store GCAM Parameters
Enable
Hex Char 3, bit 4
1 = Records additional GCAM parameters
when an Event occurs, for added
diagnostic ability of GCAM parameters,
0 = Records standard set of GCAM Data
NOTE: GCAM Event data is stored for
every event, independent of this setting.
Store GFM Parameters
Enable
Hex Char 3, bit 3
1 = Records additional GFM parameters
when an Event occurs, for added
diagnostic ability of Platform parameters,
0 = Records standard set of GFM Data
NOTE: GFM Event data is stored for every
event, independent of this setting.