User's Manual

Table Of Contents
SYSTEM DESCRIPTION AND INSTALLATION MANUAL
T
3
CAS/Part No.9005000
NOTE:
The MSB is the left most bit in the Hex value (MSB .. LSB).
Figure 6-36: ACD Option Page (Page 12/25) Call Out Option Enabled
Table 6-4: ACD Callout Options
Callout Option
ACD Callout Option
Bit Option
ACD Callout Option Bit Setting
Bank Angle Callout Enable
Flag
Hex Char 1 (MSB), bit
4
1 = Bank Angle Callout Enabled,
0 = Bank Angle Callout Disabled
DH/MDA Switch Available
Flag
Hex Char 1 (MSB), bit
3
1 = DH/MDA Switch Available,
0 = DH/MDA Switch Not Available
Decision Height Callout
Enable Flag
Hex Char 1 (MSB), bit
2
1 = Decision Height Callout Enabled,
0 = Decision Height Callout Disabled
Minimums Callout Enable Flag
Hex Char 1 (MSB), bit
1
1 = Minimums Callout Enabled,
0 = Minimums Callout Disabled
Minimums-Minimums Callout
Enable Flag
Hex Char 2 (MSB), bit
4
1 = Minimums-Minimums Callout
Enabled,
0 = Minimums-Minimums Callout
Disabled
Approaching Decision Height
Callout Enable Flag
Hex Char 2 (MSB), bit
3
1 = Approaching Decision Height
Callout Enabled,
0 = Approaching Decision Height
Callout Disabled
Approaching Minimums
Callout Enable Flag
Hex Char 2 (MSB), bit
2
1 = Approaching Minimums Callout
Enabled,
0 = Approaching Minimums Callout
Disabled
1,000 ft (304.8 m) Callout
Enable Flag
Hex Char 2 (MSB), bit
1
1 = 1,000 ft (304.8 m) Callout
Enabled,
0 = 1,000 ft (304.8 m) Callout
Disabled
Pub. No. 8600200-001, Revision 004
34-45-29
6-39
04 Nov2014
Use or disclosure of information on this page is subject to the restrictions in the proprietary notice of this document.