User's Manual
Table Of Contents
- T3CAS_Section_5
- 5 Adjustment/Test
- 1. General
- 2. Equipment
- 3. Initial Harness Checkout (New Installations Only)
- 4. System Self-Tests
- 5. Return-to-Service Test
- 6. Operational Software Loading Using an ARINC 615A Portable Data Loader or Compact Flash Card
- 7. Downloading Information from the TP3PCAS Using a CF Card
- 1. Obtain a New or Blank Compact Flash (CF) card.
- 2. Copy to the New or Blank CF card the appropriate ‘Header File’
- a) Header files are files copied to the New or Blank CF card that will instruct the computer unit what is desired to be downloaded.
- b) Header files needed to download Maintenance Data, Event Data and CRC Part Numbers can be obtained from ACSS Customer Services at +1-623-445-7070 or crc.acss@l-3com.com.
- 3. For downloading Maintenance Data, Event Data or CRC Part Numbers the aircraft does not need to be in an on-ground configuration.
- 4. Apply power to the computer unit.
- 5. Insert the CF card.
- 6. For ACSS part numbers 9005000-10000, -10101, -10202, and -10204 the DATA STATUS LED will UblinkU green once; this indicates the unit recognized that a CF card was inserted.
- 7. For ACSS part numbers 9005000-11203, -11801 and -55801 the DATA STATUS LED will UblinkU green while reading the header file and performing the action defined in the header file.
- 8. Flight Data Recording
- 1. T3CAS part numbers 9005000-10000, -10101, -10202, and -10204 only support FAT16 CF card formatting. T3CAS part numbers 9005000-11203, -11801 and -55801 support both FAT16 and FAT32 CF card formatting.
- B. Flight Data
- 1. Obtain a New or Blank CF Card.
- 2. Copy to the New or Blank CF Card the Appropriate Header File.
- 3. Header files are files copied to the New or Blank CF card that will instruct the computer unit what is desired to be downloaded.
- 4. For Flight Data Recording, the aircraft does not need to be in an on-ground configuration.
- 5. Apply power to the computer unit.
- 6. Insert the CF card.
- B. Flight Data
- 9. Downloaded Maintenance Data, Event Data And Flight Data May Be Sent To ACSS Customer Services For Analysis
- 5 Adjustment/Test
- T3CAS_Section_6
- T3CAS_Section_7
- 7 Maintenance Practices
- 1. General
- 2. Equipment and Materials
- 3. Procedure for the TP3PCAS Computer Unit
- 4. Procedure for the APM (Not applicable for part numbers 9005000-10000, -10101, -10202, -10204, or -11203)
- 5. Procedure for the Directional Antenna
- 6. Procedure for the Omnidirectional Antenna (Applicable to part numbers 9005000-11203, -11801 and -55801)
- 7. Procedure for the Control Panel
- 8. Procedure for the VSI/TRA Display
- 9. Instructions for Continued Airworthiness, FAR Part 25.1529
- 7 Maintenance Practices
- T3CAS_Section_8
- T3CAS_Section_9
- T3CAS_Section_10
- T3CAS_Appendix_A
SYSTEM DESCRIPTION AND INSTALLATION MANUAL
T
3
CAS/Part No.9005000
The T
3
CAS Maintenance System Test Page displays “LRU FAIL” (FAIL
displayed in red) on row 3 if the “Terrain Awareness System Fail” aural
has been annunciated and the “Terrain Awareness LRU Pass” aural has
not been annunciated.
NOTE:
There is no LRU fail aural annunciation. However, the absence
of an “LRU PASS” aural annunciation along with a “Terrain
Awareness System Fail” aural annunciation indicates that the
T
3
CAS LRU has failed.
The T
3
CAS Maintenance System Test Page displays “SYS PASS”
(PASS displayed in green) on row 4 if the “Terrain Awareness System
Pass” aural has been annunciated.
The T
3
CAS Maintenance System Test Page displays “SYS FAIL” (FAIL
displayed in red) on row 4 if either the “Terrain Awareness System Fail”
or “Terrain Awareness System Unavailable” aural has been annunciated.
(e) ACD Options Pages
The T
3
CAS Maintenance ACD Options Pages follow the System Test
page.
The T
3
CAS Maintenance ACD Options Pages display a “-” in place of
each character if the corresponding data (Callout Options, Configuration
Options binary and enumerated, and Volume Levels) is invalid or is not
available. For example, if the High-Impedance Volume Level is not
available in place of the volume level value, “---” (3 dashes) will be
displayed.
If the Call Out Enable is disabled, the ACD Options Page 12/25 will
display “ALL CALL OUT OPTS DISABLED” as shown in Figure 6-35.
NOTE:
If the callout options are disabled, only the ACD Options Page
12/25, is affected. All remaining pages, configuration (binary
and enumerated) data and volume level will still be displayed.
Figure 6-35: ACD Option Page (Page 12/25) – Call Out Options Disabled
If the Call Out Enable is enabled, the ACD Options Page 12/25 will
display the hex representation of the Call Out Options as shown in
Figure 6-36. The correlation table for the displayed hex values is shown
in Table 6-4. In the example shown in Figure 6-36, all options are
selected to enabled.
6-38
04 Nov 2014
34-45-29
Pub. No. 8600200-001, Revision 004