User's Manual

Table Of Contents
SYSTEM DESCRIPTION AND INSTALLATION MANUAL
T
3
CAS/Part No.9005000
(a) The DATA STATUS LED will then blink green to indicate the unit is
reading the CF card and verifying the files on the card, programming the
files to memory, and finally performing a CRC on the programmed files.
(b) The DATA STATUS LED will change from
blinking to solid green when
the load is complete and there were no errors.
NOTE:
An unsuccessful upload is indicated by amber DATA STATUS LED
displayed during the upload process. The LED correlations are listed in
Table 5-4.
(9) Once the upload is successful, the Data Status LED changes to a continuous
green indication. Remove the CF card from the T
3
CAS computer unit front panel.
(See Figure 5-6.)
CAUTION: USE EXTRACTOR PUSHBUTTON TO REMOVE THE CF
CARD.
(10) Close the compact flash (CF) card protective door.
(11) All LEDs will illuminate, which indicates a T
3
CAS computer unit restart.
(12) All LEDs will extinguish when the unit has restarted. The unit is ready. Verify part
numbers in accordance with the instructions given in Section 6.C.
Figure 5-5: Compact Flash Card Access Port and LRU Identification Label
Pub. No. 8600200-001, Revision 004
34-45-29
5-21
04 Nov 2014
Use or disclosure of information on this page is subject to the restrictions in the proprietary notice of this document.