User's Manual

Table Of Contents
SYSTEM DESCRIPTION AND INSTALLATION MANUAL
T
3
CAS/Part No.9005000
The maintenance report is initiated under the following conditions:
The ACD entry for BITE_FAULT_AURALS is enabled and the TAWS flight
deck self-test pushbutton/switch transitions from not initiated to initiated, and
is held active for a period greater than 3 seconds.
AND
No other self-test operation (self-test, active fault annunciation, past fault
annunciation, maintenance pages) is currently active.
NOTE:
Further definition and execution detail on the self-test discrete input is
defined in the ASDB and may vary from aircraft to aircraft.
The maintenance report operations execute the following in the order listed:
(a) Standard self-test
(b) Active fault annunciation
1 Aurally annunciate “ACTIVE EXTERNAL FAULTS”
2 Annunciate each Active External Fault
(c) Past Fault annunciation
1 Aurally annunciate faults for the past five flight legs as shown in
Figure 5-3.
5-12
04 Nov 2014
34-45-29
Pub. No. 8600200-001, Revision 004
Use or disclosure of information on this page is subject to the restrictions in the proprietary notice of this document.