(10) Maximum Cruising True Airspeed. (See Table 4-28.)
Table 4-28: Maximum Cruising True Airspeed
Configuration
Number
Description
Connect RTP
5K to:
1
Airspeed between 300 and 600 KTS
Open
2
Airspeed up to 75 KTS
RTP-13B
3
Airspeed between 75 and 150 KTS
RTP-13C
4 Airspeed between 150 and 300 KTS RTP-13D
5 No maximum airspeed available RTP-13E
6
Airspeed between 600 and 1200
KTS
RTP-13F
7 Airspeed more than 1200 KTS RTP-13G
8
Not assigned
RTP-13H
9
Invalid
RTP-13K
(11) Cold Temperature Compensation Function. (See Table 4-29.)
Table 4-29: Cold Temperature Compensation Function
Configuration
Number
Spare Spare
Cold
Temperature
Compensation
Function
Connect RTP
7K to:
1 Disable Disable Full Open
2
Disable
Disable
Light
RTP-13B
3(Spare Conf.)
Disable
Enable
Full
RTP-13C
4(Spare Conf.)
Disable
Enable
Light
RTP-13D
5 (Spare Conf.) Enable Disable Full RTP-13E
6(Spare Conf.) Enable Disable Light RTP-13F
7(Spare Conf.)
Enable
Enable
Full
RTP-13G
8 (Spare Conf.)
Enable
Enable
Light
RTP-13H
9 (Invalid)
Invalid
Invalid
Invalid
RTP-13K
COLD TEMPERATURE COMPENSATION FUNCTION:
Enable - Cold Temperature Compensation applied to barometric altitude used for
altitude position determination.
Disable - Cold Temperature Compensation disabled.
Pub. No. 8600200-001, Revision 004
34-45-29
4-131
04 Nov 2014
Use or disclosure of information on this page is subject to the restrictions in the proprietary notice of this document.