User's Manual

Table Of Contents
SYSTEM DESCRIPTION AND INSTALLATION MANUAL
T
3
CAS/Part No.9005000
Table 4-23: Alternate Alert Priority Management/Predictive Windshear Present/Blank Angle
Function
Configuration
Number
Alternate
Alert Priority
Management
(TSO 151)
(NOTE)
Predictive Windshear
Present
Bank Angle
Function
Connect RTP
7D to:
1 Disable Not Present Disable Open
2 Disable Not Present Enable RTP-13B
3
Disable
Present
Disable
RTP-13C
4
Disable
Present
Enable
RTP-13D
5
Enable
Not Present
Disable
RTP-13E
6 Enable Not Present Enable RTP-13F
7 Enable Present Disable RTP-13G
8
Enable
Present
Enable
RTP-13H
9 (Invalid)
Invalid
Invalid
Invalid
RTP-13K
NOTE:
ALTERNATE ALERT PRIORITY MANAGEMENT (TSO 151) only
applies to 9005000-10000, -10101, -10202, -10204, and -11203. For
other Part No. it is a Spare.
Enable - Future provision to activate the alert priority management as defined in
TSO C151.
Disable For part numbers 9005000-10000, -10101, -10202, -10204, and -
11203, the Alert priority management is per OEM definition (alert priority
management performed externally of T
3
CAS).
PREDICTIVE WINDSHEAR PRESENT:
Present - Predictive Windshear is installed (Pop-up alert priorities managed
accordingly).
Not Present - Predictive Windshear not installed.
BANK ANGLE FUNCTION:
Enabled - Bank Angle Call Out enabled (Wide Body Only).
Disabled - Bank Angle Call Out disabled.