User's Manual
Table Of Contents
- T3CAS_Section_5
- 5 Adjustment/Test
- 1. General
- 2. Equipment
- 3. Initial Harness Checkout (New Installations Only)
- 4. System Self-Tests
- 5. Return-to-Service Test
- 6. Operational Software Loading Using an ARINC 615A Portable Data Loader or Compact Flash Card
- 7. Downloading Information from the TP3PCAS Using a CF Card
- 1. Obtain a New or Blank Compact Flash (CF) card.
- 2. Copy to the New or Blank CF card the appropriate ‘Header File’
- a) Header files are files copied to the New or Blank CF card that will instruct the computer unit what is desired to be downloaded.
- b) Header files needed to download Maintenance Data, Event Data and CRC Part Numbers can be obtained from ACSS Customer Services at +1-623-445-7070 or crc.acss@l-3com.com.
- 3. For downloading Maintenance Data, Event Data or CRC Part Numbers the aircraft does not need to be in an on-ground configuration.
- 4. Apply power to the computer unit.
- 5. Insert the CF card.
- 6. For ACSS part numbers 9005000-10000, -10101, -10202, and -10204 the DATA STATUS LED will UblinkU green once; this indicates the unit recognized that a CF card was inserted.
- 7. For ACSS part numbers 9005000-11203, -11801 and -55801 the DATA STATUS LED will UblinkU green while reading the header file and performing the action defined in the header file.
- 8. Flight Data Recording
- 1. T3CAS part numbers 9005000-10000, -10101, -10202, and -10204 only support FAT16 CF card formatting. T3CAS part numbers 9005000-11203, -11801 and -55801 support both FAT16 and FAT32 CF card formatting.
- B. Flight Data
- 1. Obtain a New or Blank CF Card.
- 2. Copy to the New or Blank CF Card the Appropriate Header File.
- 3. Header files are files copied to the New or Blank CF card that will instruct the computer unit what is desired to be downloaded.
- 4. For Flight Data Recording, the aircraft does not need to be in an on-ground configuration.
- 5. Apply power to the computer unit.
- 6. Insert the CF card.
- B. Flight Data
- 9. Downloaded Maintenance Data, Event Data And Flight Data May Be Sent To ACSS Customer Services For Analysis
- 5 Adjustment/Test
- T3CAS_Section_6
- T3CAS_Section_7
- 7 Maintenance Practices
- 1. General
- 2. Equipment and Materials
- 3. Procedure for the TP3PCAS Computer Unit
- 4. Procedure for the APM (Not applicable for part numbers 9005000-10000, -10101, -10202, -10204, or -11203)
- 5. Procedure for the Directional Antenna
- 6. Procedure for the Omnidirectional Antenna (Applicable to part numbers 9005000-11203, -11801 and -55801)
- 7. Procedure for the Control Panel
- 8. Procedure for the VSI/TRA Display
- 9. Instructions for Continued Airworthiness, FAR Part 25.1529
- 7 Maintenance Practices
- T3CAS_Section_8
- T3CAS_Section_9
- T3CAS_Section_10
- T3CAS_Appendix_A
SYSTEM DESCRIPTION AND INSTALLATION MANUAL
T
3
CAS/Part No.9005000
Table 4-14: TAWS/XPDR Programmable Discrete Outputs
Digital Signal Definition
Pin#
Notes
Ground Discrete Output RTP-13B
GPWS Caution /TAWS/XPDR Lamp 500 mA
Strobed Output Pin
Ground Discrete Output RTP-13C
Spare /TAWS/XPDR 500 mA
Strobed Output Pin
Ground Discrete Output RTP-13D
GPWS Warning /TAWS/XPDR Lamp 500 mA
Strobed Output Pin
Ground Discrete Output RTP-13E
Spare /TAWS/XPDR 500 mA
Strobed Output Pin
Ground Discrete Output RTP-13F
Spare /TAWS/XPDR 500 mA
Strobed Output Pin
Ground Discrete Output RTP-13G
Spare /TAWS/XPDR 500 mA
Strobed Output Pin
Ground Discrete Output RTP-13H
Spare /TAWS/XPDR 500 mA
Strobed Output Pin
Ground Discrete Output RTP-13J
GND Disc Output 500 mA
Terrain Display Select #1
Ground Discrete Output RTP-13K
Spare /TAWS/XPDR 500 mA
Strobed Output Pin
Ground Discrete Output RTP-14A
GND Disc Output 500 mA
Terrain Dispay Select #2
Ground Discrete Monitor
Output
RTP-14B GPWS Monitor 500 mA
Ground Discrete Monitor
Output
RTP-14C Terrain Not Available Monitor 250 mA
Ground Discrete Monitor
Output
RTP-14D Terrain Monitor 250 mA
(a) Discrete Input Ground/Open
T
3
CAS provides ground/open discrete inputs for aircraft level discrete
interfaces. The GROUND and OPEN logic states are determined as
follows:
GROUND ≤ 3.5 V dc at the input OR a resistance of less than 10
ohms to ground.
OPEN ≥ 14.0 V dc at the input OR a resistance of greater than 100k
ohms to ground.
Pub. No. 8600200-001, Revision 004
34-45-29
4-115
04 Nov 2014
Use or disclosure of information on this page is subject to the restrictions in the proprietary notice of this document.