User's Manual

SYSTEM DESCRIPTION AND INSTALLATION MANUAL
T
3
CAS/Part No.9005000
F. TAWS Terrain Hazard Display
For T
3
CAS installations with the TAWS function enabled, at least one TAWS terrain
hazard display is required. ARINC 708 and ARINC 429 WXR display and EFIS interfaces
are supported. Figure 3-12 shows a typical single ARINC 708 terrain hazard display
interface. The T
3
CAS dual-independent terrain hazard display I/O supports dual ARINC
708 and dual ARINC 429 terrain hazard display systems. Figure 3-12 shows a typical
single ARINC 708 terrain hazard display and display interface with annunciator switch
panels. The TERR and WXR select switches shown are momentary but alternate action
switches are also supported. The terrain INHIBIT or OVRD switches are alternate action
switches and are typically guarded.
3-24
04 Nov 2014
34-45-29
Pub. No. 8600200-001, Revision 004
Use or disclosure of information on this page is subject to the restrictions in the proprietary notice of this document.