User Instructions

SECURITY NOTATION SPEC
NO.
IT4061400-907
SEE PAGE INDEX
FOR THIS SHEET
REV LETTER
CAGE
CODE
58960
REV LTR
SEE THE TITLE PAGE FOR PROPRIETARY AND DATA RIGHTS NOTATIONS.
REV TEST SPECIFICATION PROCEDURE SPECIFICATION
LTR NO. OPR LIMITS C TEST DESCRIPTION SWITCH POS C WORK STEPS MFG LIMITS
AW/CRITICAL NOTATION
SUPPLEMENTS
94
SECURITY NOTATION PAGE
15101-000 (REV 970213 BCAS ASF5900/ENG_SPEC.DOT) (REV 07/18/2000 -OFC97-DATA SERVICES) HONEYWELL INTERNATIONAL INC.
ENGINEERING
SPECIFICATION
27.2 ON Verify that the BOT ANT
and XPDR FAIL indicator
lamps are illuminated
when the TEST button is
pushed momentarily for
any version that is prior to
a -905 MOD E.
Press the TEST button on
the UUT. Verify that, on
the front panel of the
Mode S Transponder, the
BOT ANT and XPDR FAIL
indicator lamps are
illuminated when the
TEST button is pushed
momentarily for any
version that is prior to a
-905 MOD E.
ON
Verify that BOT ANT FAIL
and XPDR PASS indicator
lamps are illuminated
when the TEST button is
pushed momentairly for a
-905 MOD E.
Press the TEST button on
the UUT. Verify that, on
the front panel of the
Mode S Transponder, the
BOT ANT FAIL and XPDR
PASS indicator lamps are
illuminated when the
TEST button is pushed
momentarily for a -905
MOD E.
Turn off UUT. Turn off UUT.
Replace cable on BOT
ANT port.
On the Mode S interface
panel, replace BOT ANT
cable.
28 SYSTEM STATUS
SYSTEM STATUS
Perform test setup in
accordance with tables 1
and 5.
Perform test setup in
accordance with tables 1
and 5.
With Mode S software
running, press the TEST
button on the front panel
of the UUT.
INTFC PNL
AIR/GND 1:
GROUND
AIR/GND 2:
GROUND
With Mode S software
running, press the TEST
button on the front panel
of the UUT.
Observe the front panel
LEDs. They should all
illuminate briefly (lamp
test), then display as
specified.
Observe the front panel
LEDs. They should all
illuminate briefly (lamp
test), then display as
specified.