User Instructions

SECURITY NOTATION SPEC
NO.
IT4061400-907
SEE PAGE INDEX
FOR THIS SHEET
REV LETTER
CAGE
CODE
58960
REV LTR
SEE THE TITLE PAGE FOR PROPRIETARY AND DATA RIGHTS NOTATIONS.
REV TEST SPECIFICATION PROCEDURE SPECIFICATION
LTR NO. OPR LIMITS C TEST DESCRIPTION SWITCH POS C WORK STEPS MFG LIMITS
AW/CRITICAL NOTATION
SUPPLEMENTS
93
SECURITY NOTATION PAGE
15101-000 (REV 970213 BCAS ASF5900/ENG_SPEC.DOT) (REV 07/18/2000 -OFC97-DATA SERVICES) HONEYWELL INTERNATIONAL INC.
ENGINEERING
SPECIFICATION
27.1 ON Verify that TOP ANT and
XPDR FAIL indicator
lamps are illuminated
when the TEST button is
pushed momentarily for
any version that is prior to
a -905 MOD E.
Press the TEST button on
the UUT. Verify that, on
the front panel of the
Mode S Transponder, the
TOP ANT and XPDR FAIL
indicator lamps are
illuminated when the
TEST button is pushed
momentarily for any
version that is prior to a
-905 MOD E.
ON
Verify that TOP ANT FAIL
and XPDR PASS indicator
lamps are illuminated
when the TEST button is
pushed momentarily for a
-905 MOD E.
Press the TEST button on
the UUT. Verify that, on
the front panel of the
Mode S Transponder, the
TOP ANT FAIL and XPDR
PASS indicator lamps are
illuminated when the
TEST button is pushed
momentarily for a -905
MOD E.
Turn UUT off. Turn UUT off.
Replace the TOP ANT
cable. Remove cable
from the BOT ANT port
and terminate the BOT
ANT port with an open
circuit (infinite ohm)
terminator.
On the Mode S inter-face
panel, replace the TOP
ANT cable. Remove
cable from the BOT ANT
port and terminate the
port with an open circuit
(infinite ohm) terminator.
Turn UUT on. Turn UUT on.