User Instructions

SECURITY NOTATION SPEC
NO.
IT4061400-907
SEE PAGE INDEX
FOR THIS SHEET
REV LETTER
CAGE
CODE
58960
REV LTR
SEE THE TITLE PAGE FOR PROPRIETARY AND DATA RIGHTS NOTATIONS.
REV TEST SPECIFICATION PROCEDURE SPECIFICATION
LTR NO. OPR LIMITS C TEST DESCRIPTION SWITCH POS C WORK STEPS MFG LIMITS
AW/CRITICAL NOTATION
SUPPLEMENTS
84
SECURITY NOTATION PAGE
15101-000 (REV 970213 BCAS ASF5900/ENG_SPEC.DOT) (REV 07/18/2000 -OFC97-DATA SERVICES) HONEYWELL INTERNATIONAL INC.
ENGINEERING
SPECIFICATION
18.13 PASS Observe the squitter
interval over a period of
10 seconds. The value
shall not exceed the limits
from 0.8 to 1.2 seconds.
Observe the squitter
interval on the S-1403
over a period of 10
seconds. The value shall
not exceed the limits from
0.8 to 1.2 seconds.
PASS
S-1403
ANT B: OFF
19 MODE S REPLY RATE
CAPABILITY
MODE S REPLY RATE
CAPABILITY
Perform test setup in
accordance with tables 1
and 5.
Perform test setup in
accordance with tables 1
and 5.
Interrogate the UUT with a
UF 5 interrogation at a
rate of 177 per second.
ATC-1400A
PRF: 0177
S-1403
FUNC 2
On the ATC-1400A, adjust
the PRF thumbwheels to
0177.
On the S-1403, select
FUNC 2 (SEQ - MODE S
ONLY).
Observe the following
reply characteristics. The
values shall be as
specified.
ATC-1400A
CW/NORM/
OFF: NORM
Observe the following
reply characteristics on
the ATC-1400A displays.
The values shall be as
specified.
19.1 PASS Over a period of 10
seconds, the Mode S %
reply shall not fall below
90%.
Over a period of 10
seconds, the Mode S %
reply shall not fall below
98%.
PASS
19.2 PASS Reply Frequency
1090 ± 1 MHz
Reply Frequency
1090 ± 1 MHz
PASS
19.3 PASS Reply Power
250 to 630 Watts
Reply Power
280 to 550 Watts
PASS