User Instructions

SECURITY NOTATION SPEC
NO.
IT4061400-907
SEE PAGE INDEX
FOR THIS SHEET
REV LETTER
CAGE
CODE
58960
REV LTR
SEE THE TITLE PAGE FOR PROPRIETARY AND DATA RIGHTS NOTATIONS.
REV TEST SPECIFICATION PROCEDURE SPECIFICATION
LTR NO. OPR LIMITS C TEST DESCRIPTION SWITCH POS C WORK STEPS MFG LIMITS
AW/CRITICAL NOTATION
SUPPLEMENTS
83
SECURITY NOTATION PAGE
15101-000 (REV 970213 BCAS ASF5900/ENG_SPEC.DOT) (REV 07/18/2000 -OFC97-DATA SERVICES) HONEYWELL INTERNATIONAL INC.
ENGINEERING
SPECIFICATION
18.7 128 ±
0.25 µs
Measure and record the
reply delay. Delay shall
be as specified.
Observe and record the
reply field on the S-1403.
Field shall indicate as
specified.
128 ±
0.25 µs
Mode S Reply Power
Mode S Reply Power
18.8 N/A This test measures Mode
S reply power.
This test measures Mode
S reply power.
N/A
18.9 250 to 630
Watts
Measure and record the
peak power of the first
preamble pulse of the
Mode S reply. The power
shall be as specified.
S-1403
CONTROL
MENU 2,
Pulse Power
Gate: p1
ATC-1400A
F2/P2
F1/P1: F2
On the S-1403, change
the pulse power gate to
p1. Observe and record
the XMTR PWR display
on the ATC-1400. The
display shall indicate as
specified.
280 to 550
Watts
18.10 250 to 630
Watts
Measure and record the
peak power of the last
data pulse of the Mode S
reply. The power shall be
a specified.
S-1403
CONTROL
MENU 2,
Pulse Power
Gate: P60
ATC-1400A
F2/P2
F1/P1: F2
On the S-1403, change
the pulse power gate to
P60. Observe and record
the XMTR PWR display
on the ATC-1400. The
display shall indicate as
specified.
280 to 550
Watts
18.11 <2 dB Calculate and record the
absolute value of the
transmitter droop (in dB),
using the following
formula:
Droop = ABS [10(Log
10
P1 - Log
10
P2)], where P1
and P2 are the power
measurements taken in
tests 18.9 and 18.10,
respectively. The droop
shall not exceed the
specified limits.
Calculate and record the
absolute value of the
transmitter droop (in dB),
using the following
formula:
Droop = ABS [10(Log
10
P1 - Log
10
P2)], where P1
and P2 are the power
measurements taken in
tests 18.9 and 18.10,
respectively. The droop
shall not exceed the
specified limits.
<2 dB
Squitter Monitor
Squitter Monitor
18.12 N/A S1403
FUNC 2
ANT B: +.00
On S-1403, enter FUNC 2
and turn on ANT B.
N/A