User Instructions

SECURITY NOTATION SPEC
NO.
IT4061400-907
SEE PAGE INDEX
FOR THIS SHEET
REV LETTER
CAGE
CODE
58960
REV LTR
SEE THE TITLE PAGE FOR PROPRIETARY AND DATA RIGHTS NOTATIONS.
REV TEST SPECIFICATION PROCEDURE SPECIFICATION
LTR NO. OPR LIMITS C TEST DESCRIPTION SWITCH POS C WORK STEPS MFG LIMITS
AW/CRITICAL NOTATION
SUPPLEMENTS
81
SECURITY NOTATION PAGE
15101-000 (REV 970213 BCAS ASF5900/ENG_SPEC.DOT) (REV 07/18/2000 -OFC97-DATA SERVICES) HONEYWELL INTERNATIONAL INC.
ENGINEERING
SPECIFICATION
Mode S Reply
Format
Mode S Reply
Format
18.3.1 N/A Return the RF LEVEL
knob on the ATC-1400A
to -70 dBm.
ATC-1400A
RF Lvl:
-70 dBm
Return the RF LEVEL
knob on the ATC-1400A
to -70 dBm.
N/A
Interrogate the UUT with a
Mode S UF 4
interrogation.
S-1403
UF = 04
Select UF#04 on the
S-1403.
18.3.2 DF = 04
FS = 5
DR = 00
UM = 00
AC =
+20200
ADD =
25252525
Observe the decoded
Mode S reply data. Data
shall be as specified.
Verify the AC value
agrees with the coded
altitude measured in
paragraph 11.6. (+20200
= 7710 in Gilliam code)
Observe the decoded
Mode S reply on the
S-1403 sequence menu
(S MENU) display. Data
shall indicate as specified.
Verify the AC value
agrees with the coded
altitude measured in
paragraph 11.6. (+20200
= 7710 in Gilliam code)
DF = 04
FS = 5
DR = 00
UM = 00
AC =
+20200
ADD =
25252525
Interrogate the UUT with a
Mode S UF 20
interrogation.
S-1403
UF = 20
Select UF#20 on the
S-1403.
18.3.3 DF = 04
FS = 5
DR = 00
UM = 00
AC =
+20200
ADD =
25252525
Observe the decoded
Mode S reply data. Data
shall be as specified.
Observe the decoded
Mode S reply on the
S-1403 sequence menu
(S MENU) display. Data
shall indicate as specified.
DF = 04
FS = 5
DR = 00
UM = 00
AC =
+20200
ADD =
25252525
Interrogate the UUT with a
Mode S UF 21
interrogation.
S-1403
UF = 21
Select UF#21 on the
S-1403.