User Instructions

SECURITY NOTATION SPEC
NO.
IT4061400-907
SEE PAGE INDEX
FOR THIS SHEET
REV LETTER
CAGE
CODE
58960
REV LTR
SEE THE TITLE PAGE FOR PROPRIETARY AND DATA RIGHTS NOTATIONS.
REV TEST SPECIFICATION PROCEDURE SPECIFICATION
LTR NO. OPR LIMITS C TEST DESCRIPTION SWITCH POS C WORK STEPS MFG LIMITS
AW/CRITICAL NOTATION
SUPPLEMENTS
80
SECURITY NOTATION PAGE
15101-000 (REV 970213 BCAS ASF5900/ENG_SPEC.DOT) (REV 07/18/2000 -OFC97-DATA SERVICES) HONEYWELL INTERNATIONAL INC.
ENGINEERING
SPECIFICATION
18 MODE S MTL, REPLY
FORMAT, REPLY
FREQUENCY, DELAY,
POWER, AND
SQUITTERS
MODE S MTL, REPLY
FORMAT, REPLY
FREQUENCY, DELAY,
POWER, AND
SQUITTERS
Perform test setup in
accordance with tables 1
and 5.
Perform test setup in
accordance with tables 1
and 5.
Interrogate the UUT with
Mode S UF 5 interrogation
at the standard rate.
ATC-1400A
PRF: 0045
Select 0045 on the PRF
thumbwheels of the
ATC-1400A.
S-1403
FUNC 2
ANT B: OFF
Select FUNC 2 (SEQ -
MODE S ONLY) on the
S-1403.
Mode S MTL
Mode S MTL
18.1 N/A Set interrogation level to -
70 dBm.
ATC-1400A
RF Lvl: -70
Set the RF level on the
1400A to -70 dBm.
N/A
18.2 DF = 05
FS = 5
DR = 00
UM = 00
ID = 7777
ADD =
25252525
Observe the Mode S reply
data. Data shall be as
specified.
ATC-1400A
CW/NORM/
OFF: NORM
Observe the decoded
Mode S reply on the
S-1403 sequence menu
(S MENU) display. Data
shall indicate as specified.
DF = 05
FS = 5
DR = 00
UM = 00
ID = 7777
ADD =
25252525
18.3 -77 ± 3 dBm Slowly decrement the
interrogation level in 1-dB
steps until the % reply is
less than 90%, then
increment by 1 dB. The
interrogation level shall be
as specified. Record the
value.
Slowly decrement the RF
LEVEL knob on the
ATC-1400A in 1-dB steps
until the % reply display
indicates less than 90%,
then increment the RF
level by 1 dB. The RF
level shall indicate as
specified. Record the
value.
-77 ± 3 dBm