User Instructions

SECURITY NOTATION SPEC
NO.
IT4061400-907
SEE PAGE INDEX
FOR THIS SHEET
REV LETTER
CAGE
CODE
58960
REV LTR
SEE THE TITLE PAGE FOR PROPRIETARY AND DATA RIGHTS NOTATIONS.
REV TEST SPECIFICATION PROCEDURE SPECIFICATION
LTR NO. OPR LIMITS C TEST DESCRIPTION SWITCH POS C WORK STEPS MFG LIMITS
AW/CRITICAL NOTATION
SUPPLEMENTS
78
SECURITY NOTATION PAGE
15101-000 (REV 970213 BCAS ASF5900/ENG_SPEC.DOT) (REV 07/18/2000 -OFC97-DATA SERVICES) HONEYWELL INTERNATIONAL INC.
ENGINEERING
SPECIFICATION
16 ATCRBS ONLY ALL-
CALL, SHORT P4
POSITION
ATCRBS ONLY ALL-
CALL, SHORT P4
POSITION
Perform test setup in
accordance with tables 1
and 5.
Perform test setup in
accordance with tables 1
and 5.
Interrogate the UUT with
an ATCRBS Mode A
interrogation with short P4
of adjustable position.
Interrogate at the
standard rate.
ATC-1400A
PRF: 0450
SLS/ECHO:
OFF
XPDR MDE A
Turn PRF thumbwheels to
450 Hz. Turn SLS/ECHO
switch to OFF position.
Turn the XPDR MODE
CNTL to the MODE A
position.
S-1403
FUNC 3,
(ACS,A)
P4:CAL,
Dv = 0
Select FUNC 3 (ACS).
Within the FUNC 3 menu,
select ACS, A and
P4:CAL.
Adjust the position of the
P4 pulse on S-1403 as
shown in the table below.
P4 Dv indicates the
amount by which the P4
position will move from
nominal. The % ATCRBS
reply for each position
shall be as shown.
ATC-1400A
CW/NORM/
OFF: NORM
On the S-1403, adjust the
position of the P4 pulse as
shown in the table below.
P4 Dv indicates the
amount by which the P4
position will move from
nominal. The % ATCRBS
reply for each position
shall be as shown. (Read
the % reply display on the
ATC-1400A.)
16.1 <10%
>90%
<10%
<10%
>90%
P4 Dv
0µs
+0.3 µs
+0.05 µs
-0.05 µs
-0.3 µs
P4 Dv
0µs
+0.3 µs
+0.05 µs
-0.05 µs
-0.3 µs
<2%
>98%
<2%
<2%
>98%