3.6 Standard rate and power for ATCRBS and Mode S interrogations are defined as follows:
ATCRBS: 450 Hz, -50 dBm
Mode S: 45 Hz, -50 dBm
3.7 Input discrete signal standards are as follows:
GND - <3.5 V at 100 mA
OPEN - >100k ohms
+5V - 5 ± 1 V dc at 20 mA
+28V - >18 V dc
3.8 Output discrete signal standards are as follows:
GND - <3.5 V dc
OPEN - >100k ohms
+28V - >18 V dc
3.9 Notes on entering data into the IFR S-1403 are listed below:
3.9.1 Data is entered by use of the cursor keys, slew knob, and numeric keypad. Use the cursor keys to
move between input fields (the cursor will not move to an output/display field). Once in the
desired field, use the slew knob and/or numeric keypad to alter the data.
3.9.2 Some fields require the data to toggle through one or more states (for example, the SPR: ON/OFF
field). Use the ON/CAL button to toggle such fields.
3.9.3 Some input fields can be moved through a range of numeric values (for example, the Dv=CAL
field). These fields must first be toggled out of the CAL state and into the data entry mode. The
slew knob and numeric keypad can then be used to provide the desired value.
3.9.4 Some fields require the ENTER key to be pressed after the required data has been selected (for
example, the UF= field).
3.10 Notes and a list of HP 64000 command files (Honeywell Part No. MT4061400-902) are as follows:
3.10.1 The total execution time of this Integrated Test Procedure may be greatly reduced by using the HP
64000 command files listed in paragraph 3.10.3. These command files automatically execute
many keystrokes found in certain tests and match statement-for-statement (excluding 'wait'
statements) the steps found in the IT work steps.
3.10.2 After executing the 'HW' batch file (see paragraph 3.3), execute the command file by typing the
filename (using all caps) into the HP 64000 and pressing RETURN. Most command files pause to
allow the operator to record data. Press any key to resume command file execution.