User Instructions

SECURITY NOTATION SPEC
NO.
IT4061400-907
SEE PAGE INDEX
FOR THIS SHEET
REV LETTER
CAGE
CODE
58960
REV LTR
SEE THE TITLE PAGE FOR PROPRIETARY AND DATA RIGHTS NOTATIONS.
REV TEST SPECIFICATION PROCEDURE SPECIFICATION
LTR NO. OPR LIMITS C TEST DESCRIPTION SWITCH POS C WORK STEPS MFG LIMITS
AW/CRITICAL NOTATION
SUPPLEMENTS
73
SECURITY NOTATION PAGE
15101-000 (REV 970213 BCAS ASF5900/ENG_SPEC.DOT) (REV 07/18/2000 -OFC97-DATA SERVICES) HONEYWELL INTERNATIONAL INC.
ENGINEERING
SPECIFICATION
14 ATCRBS
INTERROGATION PULSE
POSITION TOLERANCE
(MODE C)
ATCRBS
INTERROGATION PULSE
POSITION TOLERANCE
(MODE C)
Perform test setup in
accordance with tables 1
and 5.
Perform test setup in
accordance with tables 1
and 5.
Interrogate the UUT with
an ATCRBS Mode C
interrogation at the
standard rate, with
adjustable P1-P3 spacing.
ATC-1400A
XPDR MDE C
PRF: 0450
Turn XPDR MODE control
to the C position. Turn
PRF thumbwheels to 450
Hz.
Use the following table to
set the spacing of the P1-
P3 pulses. The resulting
ATCRBS % reply shall be
as specified.
ATC-1400A
CW/NORM/
OFF: NORM
Use the following table to
set the XPDR P2/P3 DEV
thumbwheels and P3
switch on the ATC-1400A.
The resulting ATCRBS %
reply shall be as specified.
14.1 >90%
>90%
<10%
<10%
Dev Delta
P1-P3
0.20 - 20.8 µs
0.20 + 21.2 µs
1.00 + 22.0 µs
1.00 - 20.0 µs
Dev Delta
P1-P3
0.20 - 20.8 µs
0.20 + 21.2 µs
1.00 + 22.0 µs
1.00 - 20.0 µs
>98%
>98%
<2%
<2%
15 ATCRBS REPLY RATE
CAPABILITY
ATCRBS REPLY RATE
CAPABILITY
Perform test setup in
accordance with tables 1
and 5.
Perform test setup in
accordance with tables 1
and 5.