User Instructions

SECURITY NOTATION SPEC
NO.
IT4061400-907
SEE PAGE INDEX
FOR THIS SHEET
REV LETTER
CAGE
CODE
58960
REV LTR
SEE THE TITLE PAGE FOR PROPRIETARY AND DATA RIGHTS NOTATIONS.
REV TEST SPECIFICATION PROCEDURE SPECIFICATION
LTR NO. OPR LIMITS C TEST DESCRIPTION SWITCH POS C WORK STEPS MFG LIMITS
AW/CRITICAL NOTATION
SUPPLEMENTS
67
SECURITY NOTATION PAGE
15101-000 (REV 970213 BCAS ASF5900/ENG_SPEC.DOT) (REV 07/18/2000 -OFC97-DATA SERVICES) HONEYWELL INTERNATIONAL INC.
ENGINEERING
SPECIFICATION
11.4.3 -76 ± 4 dBm Slowly decrement the
interrogation level in 1-dB
steps until the % reply is
less than 90%, then
increment by 1 dB. The
interrogation level shall be
as specified. Record the
value.
Slowly decrement the RF
LEVEL knob on the
ATC-1400A in 1-dB steps
until the % reply indicates
less than 90%, then
increment the RF level by
1 dB. The RF level shall
indicate as specified.
Record the value.
-76 ± 4 dBm
11.4.4 N/A Interrogate the UUT with
an ATCRBS Mode C
interrogation at the
standard rate.
ATC-1400A
XPDR MDE C
CW/NORM:
NORM
Turn XPDR MODE control
to MODE C position,
CW/NORM/OFF to
NORM.
N/A
Set the interrogation level
to -70 dBm.
ATC-1400A
RF Lvl: -70
Set ATC-1400A RF level
to -70 dBm.
11.4.5 -76 ± 4 dBm Slowly decrement the
interrogation level in 1-dB
steps until the % reply is
less than 90%, then
increment by 1 dB. The
interrogation level shall be
as specified. Record the
value.
Slowly decrement the RF
LEVEL knob on the
ATC-1400A in 1-dB steps
until the % reply indicates
less than 90%, then
increment the RF level by
1 dB. The RF level shall
indicate as specified.
Record the value.
-76 ± 4 dBm
11.4.6 <1.0 dB Compare values obtained
in tests 11.4.3 and 11.4.5.
Value obtained in 11.4.3
shall be equal to that
obtained in 11.4.5 ±1.0
dB.
Compare values obtained
in tests 11.4.3 and 11.4.5.
Value obtained in 11.4.3
shall be equal to that
obtained in 11.4.5 ±1.0
dB.
<1.0 dB
ATCRBS MTL at 1030.2
MHZ, Top and Bottom
Antennas Switched
ATCRBS MTL at 1030.2
MHZ, Top and Bottom
Antennas Switched