User Instructions

SECURITY NOTATION SPEC
NO.
IT4061400-907
SEE PAGE INDEX
FOR THIS SHEET
REV LETTER
CAGE
CODE
58960
REV LTR
SEE THE TITLE PAGE FOR PROPRIETARY AND DATA RIGHTS NOTATIONS.
REV TEST SPECIFICATION PROCEDURE SPECIFICATION
LTR NO. OPR LIMITS C TEST DESCRIPTION SWITCH POS C WORK STEPS MFG LIMITS
AW/CRITICAL NOTATION
SUPPLEMENTS
66
SECURITY NOTATION PAGE
15101-000 (REV 970213 BCAS ASF5900/ENG_SPEC.DOT) (REV 07/18/2000 -OFC97-DATA SERVICES) HONEYWELL INTERNATIONAL INC.
ENGINEERING
SPECIFICATION
11.2 ID 0077 Observe the 4096 code
returned by the UUT.
Code shall be as
specified.
ATC-1400A
CW/NORM/
OFF: NORM
DPLY SEL:
XPDR CODE
Observe the XPDR CODE
display. Display shall
indicate as specified.
ID 0077
11.3 250 TO 630
Watts
Measure and record the
bottom antenna F1 pulse
power. The power shall
be within the limits
specified.
ATC-1400A
F2/P2
F1/P1: F1
On the ATC-1400A,
observe and record the
XMTR PWR display. This
measurement is the
bottom antenna F1 power,
and shall be within the
limits specified.
280 to 550
Watts
11.4 -76 ± 4 dBm Slowly decrement the
interrogation level in 1-dB
steps until the % reply is
less than 90%, then
increment by 1 dB. The
interrogation level shall be
as specified. Record the
value.
Slowly decrement the RF
LEVEL knob on the
ATC-1400A in 1-dB steps
until the % reply indicates
less than 90%, then
increment the RF level by
1 dB. The RF level shall
indicate as specified.
Record the value.
-76 ± 4 dBm
Interrogate the UUT with
an ATCRBS Mode A
interrogation at the
standard rate.
ATC-1400A
XPDR MDE A
PRF: 0450
Turn XPDR MODE control
to MODE A position. Turn
PRF thumbwheels to 450
Hz.
ATCRBS MTL at
1030.0 MHz
ATCRBS MTL at
1030.0 MHz
11.4.1 N/A Set the interrogation
frequency to 1030.0 MHz.
ATC-1400A
DSPLY SEL:
FREQ
FREQ and
DELTA F: as
required
Turn thumbwheels on
FREQ SELECT and
DELTA F until FREQ
DISPLAY indicates
1030.00 MHz.
N/A
Set the interrogation level
to -70 dBm.
ATC-1400A
RF Lvl: -70
Set ATC-1400A RF level
to -70 dBm.
11.4.2 ID 0077 Observe the 4096 code
returned by the UUT.
Code shall be as
specified.
ATC-1400A
CW/NORM/
OFF: NORM
DPLY SEL:
XPDR CODE
Observe the XPDR CODE
display. Display shall
indicate as specified.
ID 0077