User Instructions

SECURITY NOTATION SPEC
NO.
IT4061400-907
SEE PAGE INDEX
FOR THIS SHEET
REV LETTER
CAGE
CODE
58960
REV LTR
SEE THE TITLE PAGE FOR PROPRIETARY AND DATA RIGHTS NOTATIONS.
REV TEST SPECIFICATION PROCEDURE SPECIFICATION
LTR NO. OPR LIMITS C TEST DESCRIPTION SWITCH POS C WORK STEPS MFG LIMITS
AW/CRITICAL NOTATION
SUPPLEMENTS
64
SECURITY NOTATION PAGE
15101-000 (REV 970213 BCAS ASF5900/ENG_SPEC.DOT) (REV 07/18/2000 -OFC97-DATA SERVICES) HONEYWELL INTERNATIONAL INC.
ENGINEERING
SPECIFICATION
10.13 N/A Perform test setup in
accordance with table 1.
Perform test setup in
accordance with table 1.
N/A
STBY/ON
discrete
(hardware path)
S-1403
FUNC 1
Interrogate the UUT with
an ATCRBS Mode A
interrogation at the
standard rate and power.
ATC-1400A
XPDR MODE
A
PRF: 0450
RF Lvl: -50
CW/NORM/
OFF:
NORM
Turn XPDR MODE control
knob to A position. Turn
PRF thumbwheels to 450
Hz.
Mode S
Interface
Panel
STBY/ON:
ON
10.14 >90% Observe the ATCRBS %
reply. The value shall be
as specified.
Read the % reply display
on the ATC-1400A. The
display shall indicate as
specified.
>98%
Switch the UUT to
STANDBY mode.
Mode S
Inteface
Panel
STBY/ON:
STBY
On the Mode S interface
panel, toggle the
STBY/ON switch to the
STBY position.
10.15 <10% Observe the ATCRBS %
reply. The value shall be
as specified.
Read the % reply display
on the ATC-1400A. The
display shall indicate as
specified.
<2%