User Instructions

SECURITY NOTATION SPEC
NO.
IT4061400-907
SEE PAGE INDEX
FOR THIS SHEET
REV LETTER
CAGE
CODE
58960
REV LTR
SEE THE TITLE PAGE FOR PROPRIETARY AND DATA RIGHTS NOTATIONS.
REV TEST SPECIFICATION PROCEDURE SPECIFICATION
LTR NO. OPR LIMITS C TEST DESCRIPTION SWITCH POS C WORK STEPS MFG LIMITS
AW/CRITICAL NOTATION
SUPPLEMENTS
60
SECURITY NOTATION PAGE
15101-000 (REV 970213 BCAS ASF5900/ENG_SPEC.DOT) (REV 07/18/2000 -OFC97-DATA SERVICES) HONEYWELL INTERNATIONAL INC.
ENGINEERING
SPECIFICATION
Address Address
9.24 5555H
D555H
0D20AH
0D20BH
0D20AH
0D20BH
5555H
D555H
10 INTERNAL RF
SELF-TEST
INTERNAL RF
SELF-TEST
Perform test setup in
accordance with table 4.
Set up video ASIC
according to table 4.
Mode S
Interface
Panel
STBY/ON:
ON
Perform test setup in
accordance with table 4.
Enter "END"
Disable heartbeat by
switching HBDIS* switch
on the UDE (LED should
be illuminated).
Enter "SWIT100P"
Enter "trace about
address FINISHED
break_on
measurement_complete"
Enter "run from
STARTUP". Program
takes only a fraction of a
second to run. When all
six front panel LEDs are
illuminated, program is
complete.
Enter "modify register
CACHE to 1"
Short Mode S
Bottom Antenna
Short Mode S
Bottom Antenna
10.1 N/A Initiate the self-test by
writing to memory as
shown.
Address Data
0C02EH 0031H
Enter "modify memory
0C02EH to 0031H"
Enter "display memory
0C000H thru 0C003H"
N/A
The received interrogation
data shall be as shown. Data shall indicate as
follows: