1. SCOPE
This Integrated Test Specification (IT) establishes the manufacturing and operational requirements
that the Mode S Transponder, Part No. 4061400-9XX, must meet to ensure that the unit is in
proper operating condition.
2. REFERENCE DOCUMENTS
These reference documents are not required for performance of the test procedure. The purpose
of listing these documents is to provide an aid for troubleshooting should any discrepancies occur
during the performance of the test procedure.
4061400-9XX End Item Drawing - Mode S Transponder
4061401 Outline and Installation Drawing
64980-90912 HP 64000 System Overview Reference
64980-90928 HP 64000 System Software Reference
1002-6801-000 IFR 1403 Operation/Maintenance Manual
C35-3641-05 System Control Panel User's Manual
3. GENERAL INFORMATION
3.1
All tests shall be performed under the following conditions:
Temperature = 25 ± 5 C
Relative humidity = 95% maximum
Pressure = between 20 and 32 inHg
3.2 Tests 1 thru 10 shall be performed with the HP 64000/UDE or PC/CPI emulation system attached to
the top connector of the unit under test (UUT) A1 CCA (refer to figure 1). All subsequent tests shall
be performed in a stand-alone configuration with the emulation system removed or deactivated.
Power to the UUT shall be removed before attaching or removing any interconnecting systems.