User Instructions

SECURITY NOTATION SPEC
NO.
IT4061400-907
SEE PAGE INDEX
FOR THIS SHEET
REV LETTER
CAGE
CODE
58960
REV LTR
SEE THE TITLE PAGE FOR PROPRIETARY AND DATA RIGHTS NOTATIONS.
REV TEST SPECIFICATION PROCEDURE SPECIFICATION
LTR NO. OPR LIMITS C TEST DESCRIPTION SWITCH POS C WORK STEPS MFG LIMITS
AW/CRITICAL NOTATION
SUPPLEMENTS
51
SECURITY NOTATION PAGE
15101-000 (REV 970213 BCAS ASF5900/ENG_SPEC.DOT) (REV 07/18/2000 -OFC97-DATA SERVICES) HONEYWELL INTERNATIONAL INC.
ENGINEERING
SPECIFICATION
Xmtr 0/Rcvr 0 Xmtr 0/Rcvr 0
9.1 N/A (MAINT DATA OUT/AIR
DATA 1)
(MAINT DATA OUT/AIR
DATA 1)
N/A
Connect Xmtr 0 (Maint
Data Out) to Rcvr 0 (429
Air Data 1).
Perform initial setup in
accordance with table 7.
Perform initial setup in
accordance with table 7.
Modify receiver label:
Address Data
0D220H FFAAH
Enter "modify memory
0D220H to FFAAH"
Modify transmitter data:
Address Data
0D210H AAAAH
0D211H AAAAH
Enter "modify memory
0D210H thru 0D211H to
AAAAH"
Enter "display memory
0D200 thru 0D201H"
Data should read as
follows:
Data should read as
follows: