REV TEST SPECIFICATION PROCEDURE SPECIFICATION
LTR NO. OPR LIMITS C TEST DESCRIPTION SWITCH POS C WORK STEPS MFG LIMITS
AW/CRITICAL NOTATION
SUPPLEMENTS
34
SECURITY NOTATION PAGE
15101-000 (REV 970213 BCAS ASF5900/ENG_SPEC.DOT) (REV 07/18/2000 -OFC97-DATA SERVICES) HONEYWELL INTERNATIONAL INC.
ENGINEERING
SPECIFICATION
1. Adjust the amplitude of
this signal to 9 V rms.
Read the digital value for
each synchro source,
using the following
procedure:
Read the digital value for
each synchro source,
using the following
procedure:
1. Write the appropriate
data (see following
table) to memory
location D607H.
2. Wait at least 75 µs.
3. Read location D606H.
4. Record the value.
1. Write the appropriate
data (see following
table) to memory
location D607H.
2. Enter "modify memory
0D607H to <value from
table>"
3. Enter "display memory
0D606H thru 0D606H"
4. Record the value.
The data should fall within
the range shown in the
Limits.
The data should fall within
the range shown in the
Limits.