User Instructions

SECURITY NOTATION SPEC
NO.
IT4061400-907
SEE PAGE INDEX
FOR THIS SHEET
REV LETTER
CAGE
CODE
58960
REV LTR
SEE THE TITLE PAGE FOR PROPRIETARY AND DATA RIGHTS NOTATIONS.
REV TEST SPECIFICATION PROCEDURE SPECIFICATION
LTR NO. OPR LIMITS C TEST DESCRIPTION SWITCH POS C WORK STEPS MFG LIMITS
AW/CRITICAL NOTATION
SUPPLEMENTS
32
SECURITY NOTATION PAGE
15101-000 (REV 970213 BCAS ASF5900/ENG_SPEC.DOT) (REV 07/18/2000 -OFC97-DATA SERVICES) HONEYWELL INTERNATIONAL INC.
ENGINEERING
SPECIFICATION
Sig/Lamp Sig/Lamp Sig/Lamp Sig/Lamp
6.2 OPN/ON
(Green)
GND/OFF
OPN/OFF
GND/ON
(Green)
ALT FAIL 1
ALT FAIL 2
XPDR FAIL 1
XPDR FAIL 2
ALT FAIL 1
ALT FAIL 2
XPDR FAIL 1
XPDR FAIL 2
OPN/ON
(Green)
GND/OFF
OPN/OFF
GND/ON
(Green)
Write to Output Data Word
0 and Configuration
Register 3 as shown:
Write to Output Data Word
0 and Configuration
Register 3 as shown:
(Enter "modify memory
<address> to <data>")
Address Data
0D607H 0001H
0D400H 1500H
Address Data
0D607H 0001H
0D400H 1500H
Verify the state of the
following UUT front panel
LEDs:
Verify the state of the
following UUT front panel
LEDs:
Signal Name
Signal Name
6.3 off
on
on
off
on
off
XPDRPASS
XPDRFAIL
CNTLPNL
TOPANT
BOTANT
ALTSIG
XPDRPASS
XPDRFAIL
CNTLPNL
TOPANT
BOTANT
ALTSIG
off
on
on
off
on
off
Verify the following
signals. The signal sense
shall be as specified.
Verify the following
signals. The indicator
lamps on the Mode S
interface panel (or the
signals themselves) shall
be as specified.