User Instructions

SECURITY NOTATION SPEC
NO.
IT4061400-907
SEE PAGE INDEX
FOR THIS SHEET
REV LETTER
CAGE
CODE
58960
REV LTR
SEE THE TITLE PAGE FOR PROPRIETARY AND DATA RIGHTS NOTATIONS.
REV TEST SPECIFICATION PROCEDURE SPECIFICATION
LTR NO. OPR LIMITS C TEST DESCRIPTION SWITCH POS C WORK STEPS MFG LIMITS
AW/CRITICAL NOTATION
SUPPLEMENTS
31
SECURITY NOTATION PAGE
15101-000 (REV 970213 BCAS ASF5900/ENG_SPEC.DOT) (REV 07/18/2000 -OFC97-DATA SERVICES) HONEYWELL INTERNATIONAL INC.
ENGINEERING
SPECIFICATION
5.3 X5XXH While pressing the Push
To Test button on the
front panel of the UUT,
read memory location
D605H. The value shall
be as indicated.
(X = don't care)
While pressing the Push
To Test button on the
front panel of the UUT,
enter "display memory
0D605H". The value shall
be as indicated.
(X = don't care)
X5XXH
6 OUTPUT DISCRETES
OUTPUT DISCRETES
Perform test setup in
accordance with table 2.
Perform test setup in
accordance with table 2.
Write to Output Data Word
0 and Configuration
Register 3 as shown:
Write to Output Data Word
0 and Configuration
Register 3 as shown:
(Enter "modify memory
<address> to <data>")
Address Data
0D607H 0012H
0D400H 2A00H
Address Data
0D607H 0012H
0D400H 2A00H
Verify the state of the
following UUT front panel
LEDs:
Verify the state of the
following UUT front panel
LEDs:
Signal Name
Signal Name
6.1 on
off
off
on
off
on
XPDRPASS
XPDRFAIL
CNTLPNL
TOPANT
BOTANT
ALTSIG
XPDRPASS
XPDRFAIL
CNTLPNL
TOPANT
BOTANT
ALTSIG
on
off
off
on
off
on
Verify the following
signals. The signal sense
shall be as specified.
Verify the following
signals. The indicator
lamps on the Mode S
interface panel (or the
signals themselves) shall
be as specified.