User Instructions

SECURITY NOTATION SPEC
NO.
IT4061400-907
SEE PAGE INDEX
FOR THIS SHEET
REV LETTER
CAGE
CODE
58960
REV LTR
SEE THE TITLE PAGE FOR PROPRIETARY AND DATA RIGHTS NOTATIONS.
REV
LTR
AW/CRITICAL NOTATION
SUPPLEMENTS
15
SECURITY NOTATION PAGE
15101-000 (REV 970213 BCAS ASF5900/ENG_SPEC.DOT) (REV 07/18/2000 -OFC97-DATA SERVICES) HONEYWELL INTERNATIONAL INC.
ENGINEERING
SPECIFICATION
Table 5(Cont). Initial Settings For Mode S And ATCRBS (Mode S SW Running)
(Mode S Interface Panel)
Signal Name Switch Position Signal Sense
ALT COMP OFF OPEN
ALT SRC SEL 2 GND
ALT TYPE SEL B 1 OPEN
A 1 OPEN
CNTL PNL B OPEN
AIR/GND 1 GROUND GND
AIR/GND 2 AIR OPEN
NOTE 1: Disconnect all wires from MAINT DATA OUT A, B jacks on the Mode S interface panel.
NOTE 2: Set up two ARINC sources as shown (can be provided by one 429 source with dual-label
capability):
Transmit speed:
Transmit parity:
Transmit rate:
429 Label:
429 Data:
Connect to:
(On MDS interface
panel)
SOURCE 1
LOW
ODD
168 ms
016 (octal)
1FFE48 (Hex)
CNTL DATA B
SOURCE 2
LOW
ODD
50 ms
203 (octal)
627740 (Hex)
429 ADC 1 and
429 ADC 2
NOTE 3: Run Mode S software by removing or disabling the UDE or CPI interface from the UUT and
reenergizing the unit.
NOTE 4: The UDE or CPI must be removed or disabled to allow LRU software to operate.