User Instructions

SECURITY NOTATION SPEC
NO.
IT4061400-907
SEE PAGE INDEX
FOR THIS SHEET
REV LETTER
CAGE
CODE
58960
REV LTR
SEE THE TITLE PAGE FOR PROPRIETARY AND DATA RIGHTS NOTATIONS.
REV TEST SPECIFICATION PROCEDURE SPECIFICATION
LTR NO. OPR LIMITS C TEST DESCRIPTION SWITCH POS C WORK STEPS MFG LIMITS
AW/CRITICAL NOTATION
SUPPLEMENTS
A
-40
SECURITY NOTATION PAGE
15101-000 (REV 970213 BCAS ASF5900/ENG_SPEC.DOT) (REV 07/18/2000 -OFC97-DATA SERVICES) HONEYWELL INTERNATIONAL INC.
ENGINEERING
SPECIFICATION
A10.2 5555H 0C000H thru 0C003H 0C000H thru OC003H 5555H
Long Mode S
Top Antenna
Long Mode S
Top Antenna
A10.3 N/A Initiate the self-test by
writing to memory as
shown.
Address Data
0C007H thru
0C00DH AAAAH
0C02EH 0037H
Enter "modify memory
MDS word 1#C007 thru
1#C00D to AAAA"
Enter "modify memory
MDS word 1#0C02E
0037"
N/A
Enter "display memory
MDS word from 1#C000
to 1#C007"
The received interrogation
data shall be as shown.
Data shall indicate as
follows:
Address
Address
A10.4 AAAAH 0C000H thru 0C006H 0C000H thru 0C006H AAAAH
Mode S Long Squitter
Top Antenna Pwr Vld
Mode S Long Squitter
Top Antenna Pwr Vld
A10.5 N/A Set up reply data by
writing to memory as
shown. (Send preamble
pulses only.)
Address Data
0C007H F000H
0C008H thru
0C00DH 0000H
Mode S
Interface
Panel
STBY/ON:
ON
Enter "modify memory
MDS word 1#C007 F000"
Enter "modify memory
MDS word 1#C008 thru
1#C00D to 0000"
N/A
Initiate the self-test by
writing to memory as
shown.
Address Data
0C02EH 003FH
Enter "modify memory
MDS word 1#0C02E
003F"