REV TEST SPECIFICATION PROCEDURE SPECIFICATION
LTR NO. OPR LIMITS C TEST DESCRIPTION SWITCH POS C WORK STEPS MFG LIMITS
AW/CRITICAL NOTATION
SUPPLEMENTS
A
-32
SECURITY NOTATION PAGE
15101-000 (REV 970213 BCAS ASF5900/ENG_SPEC.DOT) (REV 07/18/2000 -OFC97-DATA SERVICES) HONEYWELL INTERNATIONAL INC.
ENGINEERING
SPECIFICATION
A9.4 N/A (MAINT DATA OUT/AIR
DATA 2)
(MAINT DATA OUT/AIR
DATA 2)
N/A
Perform initial setup in
accordance with table 7.
Perform initial setup in
accordance with table 7.
Modify receiver label:
Address Data
D222H FFAAH
Enter "modify memory
MDS word 1#0D222
FFAAH"
Modify transmitter data:
Address Data
D210H AAAAH
D211H AAAAH
Enter "modify memory
MDS word 1#D210 thru
1#D211 to AAAA"
Enter "display memory
MDS word from 1#D202
to 1#D203"
Data should read as
follows:
Data should read as
follows:
Address
Address
A9.5 AAAAH
2AAAH
D202H
D203H
D202H
D203H
AAAAH
2AAAH
On Mode S interface
panel, remove
connections on 429 ADC
#2 and reconnect on 575
ADC #2.
On Mode S interface
panel, remove
connections on 429 ADC
#2 and reconnect on 575
ADC #2.
Modify receiver label:
Address Data
D222H FF55H
Enter "modify memory
MDS word 1#0D222
FF55H"
Modify transmitter data:
Address Data
D210H 5555H
D211H 5555H
Enter "modify memory
MDS word 1#D210 thru
1#D211 to 5555"
Enter "display memory
MDS word from 1#D202
to 1#D203"
Data should read as
follows:
Data should read as
follows:
Address
Address